![Hyundai HRP-S09WH Service Manual Download Page 7](http://html.mh-extra.com/html/hyundai/hrp-s09wh/hrp-s09wh_service-manual_2195067007.webp)
4
Specifications
Specifications
Outdoor
Unit
Outdoor Unit Model
--
HRP-S09WH
(O)
HRP-S12WH
(O)
Compressor Trademark
CRSS
CRSS
Compressor Manufacturer
--
ELECTROMECHANICAL
(SHENYANG)
SANYO REFRIGERATION
EQUIPMENT CO.,LTD.
ELECTROMECHANICAL
(SHENYANG)
SANYO REFRIGERATION
EQUIPMENT CO.,LTD.
Compressor Model
--
C-1RZ110H3AAF
C-1RZ110H3AAF
Compressor Oil
--
FW50S
FW50S
Compressor Type
--
Rotary
Rotary
Compressor LRA.
A
25
25
Compressor RLA
A
3
3
Compressor Power Input
W
770
770
Compressor Overload Protector
--
--
--
Fan Type
--
Fan Diameter
mm
405
405
Fan Diameter
inch
15.9
15.9
Fan Motor Speed
rpm
880
880
Fan Motor Power Output
W
30
30
Fan Motor RLA
A
0.4
0.4
Fan Motor Capacitor
μF
/
/
Outdoor Unit Air Flow Volume
m
3
/h
1800
1800
Condenser Form
--
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Condenser Pipe Diameter
mm
Ф7.94
Ф7
mm
1-1.4
2-1.4
Condenser Coil Length (L×D×W)
mm
742×19.05×506
719×38.1×506
Permissible Excessive Operating
Pressure for the Discharge Side
MPa
4.3
4.3
Permissible Excessive Operating
Pressure for the Suction Side
MPa
2.5
2.5
Maximum Allowable Pressure
MPa
4.3
4.3
Cooling Operation Ambient
Temperature Range
ć
-20~52
-20~52
Heating Operation Ambient
Temperature Range
ć
-
20
~
30
-20~30
Throttling Method
--
Capillary
Capillary
Defrosting Method
--
Automatic Defrosting
Automatic Defrosting
Climate Type
--
T1
T1
Climate Zone
--
Temperate Zone
Temperate Zone
Isolation
--
I
I
Moisture Protection
--
IP24
IP24
Sound Pressure Level
dB (A)
52
53
Sound Power Level
dB (A)
61
62
Dimension (W×H×D)
mm
830X540X325
830X540X325
Dimension of Carton Box (W×H×D)
mm
876x585x363
876x585x363
Dimension of Package(W×H×D)
mm
879x605x366
879x605x366
Stacked Layers
--
5
5
Net Weight
kg
27
29
Gross Weight
kg
29.5
31.5
Refrigerant
--
R32
R32
Refrigerant Charge
kg
0.59
0.77
Connection
Pipe
Length
m
5
5
Gas Additional Charge
g/m
20
20
Outer Diameter of Liquid
Pipe(
Hyundai
Allocation)(Metric)
mm
Ф6
Ф6
Outer Diameter of Liquid Pipe(British
System Allocation)
inch
1/4"
1/4"
Outer Diameter of Gas Pipe(
Hyundai
Allocation)(Metric)
mm
Ф9.52
Ф9.52
Outer Diameter of Gas Pipe(British
System Allocation)
inch
3/8"
3/8"
Max Distance Height
m
10
10
Max Distance Length
m
20
20