HYUNDAI SINGLE PHASE VECTOR INVERTER
06
|
07
General Specifications
Item
007SF
015SF
Type
022SF
Model name
Output
Input
Control
charac-
teristic
Environment
Analog
Digital
Analog
Digital
Applicable motor capacity (kW)
Rated output capacity (kVA)
Rated output current (A)
Rated output voltage (V)
Maximum output frequency (Hz)
3-phase, 200~230 V
400 Hz
Single phase, 200~230Vac, 50/60 Hz
Voltage:
±
10% / frequency:
±
5%
Space vector PWM
V/F control, sensorless vector control
0.5 ~ 400 Hz
Max. setting frequency
÷
1000 (DC10 V, 4~20 mA)
0.01 Hz (100 Hz and less ), 0.1 Hz (100 Hz or more )
Within 0.1% of maximum output frequency
Within 0.01% of maximum output frequency
150% of rated current for 1 minute
More than 200% (at 1 Hz)
Manual torque boost can be set between 0~50%
0.1~3000 sec
Linear, S-curve, U-curve
Operating current level setting possible(20~200%), enable/disable selection
Operating current level constant, enable/disable selection
DC 0~5 V or DC 0~10 V / 4~20 mA
-10~40
℃
(no freezing)
90% RH or less(non-condensing)
-20~60
℃
(short-term temperature during transport)
Indoors without corrosive gases, flammable gases, oil mist or dust
Maximum 1000m or less above sea level, 5.9 m/s
2
or less
Forced cooling
IP20
Voltage / frequency
Power conditions
PWM method
Control method
Output frequency range
Overload rating
Starting torque
Torque boost
Acceleration/deceleration time setting
Acceleration/deceleration pattern
Current stall prevention operation level
Voltage stall prevention operation level
Analog frequency setting
Ambient temperature
Ambient humidity
Storage temperature
Installation area
Altitude and vibration
Cooling method
Environment protection
Frequency
setting resolution
Frequency
precision
N50-007SF
0.75
1.9
5.0
N50-015SF
1.5
2.7
7.0
N50-022SF
2.2
3.9
10.0
Summary of Contents for HiRun N50 Series