HYUNDAI SINGLE PHASE VECTOR INVERTER
12
|
13
Expanded Function C Mode
50.0
0.00
0.0~400 Hz (by 0.01 Hz)
Function code
Intelligent output
terminal contact
Name
Initial value Minimum value Maximum value
Unit
Code description
C01
C02
C03
C04
C05
C07
C08
C09
C10
C11
C13
C15
C17
C18
C19
C20
C21
C22
C23
0
0
14
-
Intelligent input terminal 1 setting
Intelligent input terminal 2 setting
Intelligent input terminal 3 setting
Intelligent input terminal 4 setting
Intelligent input terminal 5 setting
Intelligent input terminal 1 contact
Intelligent input terminal 2 contact
Intelligent input terminal 3 contact
Intelligent input terminal 4 contact
Intelligent input terminal 5 contact
Intelligent output terminal 11 setting
Output terminal 11 a/b contact setting
Monitor signal (FM) selection
Analog meter gain adjustment
Analog meter offset adjustment
Overload advance notice signal level setting
Acceleration arrival signal frequency setting
Deceleration arrival signal frequency setting
PID deviation level setting
1
2
3
8
0
0
0
0
0
1
0
0
100.0
0.0
100.0
0.00
10.0
0
0
0.0
-3.0
0.00
0.00
0.0
1
2
250.0
10.0
200.0
400.0
400.0
100.0
-
-
%
%
%
Hz
Hz
%
0: NO, 1: NC
0: output frequency, 1: output current, 2: output voltage
0 (45%)~250 (220%) (by 1)
-3.0~10.0% (by 0.1)
0.5
×
inverter rated current~2.0
×
inverter rated current
0.0~400 Hz (by 0.01 Hz)
0~100% (by 0.01)
0
5
-
0: NO, 1: NC
0: NO, 1: NC
0: NO, 1: NC
0: NO, 1: NC
0: NO, 1: NC
0: running signal (RUN)
1: frequency arrival signal (FA1)
2: set frequency arrival signal (FA2)
3: overload advance notice signal (OL)
4: PID control error deviation signal (OD)
5: fault alarm signal (AL)
0
0
0
0
0
0
0
0
0
14
14
14
14
1
1
1
1
1
-
-
-
-
-
-
-
-
-
0: forward run command (FW)
1: reverse run command (RV)
2: 1st multispeed command (CF1)
3: 2nd multispeed command (CF2)
4: 3rd multispeed command (CF3)
5: 4th multispeed command (CF4)
6: jog operation command (JG)
7: 2-stage acceleration/deceleration command (2CH)
8: free-run stop command (FRS)
9: external trip (EXT)
10: unattended start protection (USP)
11: software lock function (SFT)
12: analog input current selection signal (AT)
13: reset (RS)
Intelligent
input
terminal
setting
Intelligent
intput
terminal
contact
Intelligent
output
terminal
setting
Others