background image

20 

 

 

 

8.0 

 

Draining the fuel system.

 

WARNING 

 

 

All fuels are flammable and the proper precautions and procedures must be followed 

 

 

when handling fuels as they are a source of fire or explosion. 

 

 

Fuel must always be stored in the proper containers.

 

 WARNING 

 

 

When working with fuels you must always work in a well ventilated areas and avoid 

 

 

breathing petrol fumes. 

 

 

 

8.1 

 

With the fuel valve 

OFF

, remove the carburetor drain screw.

 

8.2 

 

Drain the fuel from the carburetor into a suitable container. 

8.3 

 

If the fuel in the fuel tank is to be drained, turn the fuel valve 

ON

 and drain the fuel 

 

 

from the fuel tank in to a suitable container.

 

8.4 

 

Replace the drain screw and turn the fuel valve to the 

OFF

 position.

 

 

Stoppage Time 

Recommended service procedure to prevent hard starting 

Less than 1 month 

No preparation required 

1 to 2 months 

Fill with fresh fuel  

2 months to 1 year 

Fill with fresh fuel  
Drain the carburetor float bowl 

1 year or longer 

Drain the fuel tank 
Drain the carburetor float bowl 
Pour 5ml of oil down the cylinder bore 
Fill with fresh fuel 

Use fuel conditioners that are formulated to extend storage life. 

 

8.5 

 

Remove the spark plug and pour a tablespoon of clean engine oil into the cylinder 

 

 

bore. Crank the engine a few revolutions to distribute the oil then reinstall the spark 

 

 

plug. 

8.6 

 

Slowly pull the recoil starter handle until resistance is felt. At this point the piston is 

 

 

coming up on its compression stroke and both intake and exhaust valves are closed. 

 

 

Storing the engine in this position will help to protect it from internal corrosion. 

8.7 

 

Change the engine oil. 

8.8 

 

Check the air filter and clean as necessary. 

8.9 

 

Cover the generator with a sheet to keep out dust. 

 

 

 

 

  7. STORAGE 

Summary of Contents for Hirepro HY10000

Page 1: ...1 FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference ...

Page 2: ...HECKS 8 9 3 PART LOCATIONS 10 4 FUEL OIL 11 12 5 STARTING PROCEDURE 13 6 STOPPING PROCEDURE 14 7 USING THE MACHINE 14 8 MAINTENANCE 15 18 9 TROUBLESHOOTING 19 10 STORAGE 20 11 SPECIFICATION 21 12 DECLARATIONS OF CONFORMITY 22 13 CONTACT DETAILS 23 INDEX ...

Page 3: ...e following warning signs symbols and or PPE pictograms may appear throughout this manual You MUST adhere to their warnings Failure to do so may result in personal injury to yourself or those around you DANGER Indicates a hazard which if not avoided could result in serious injury or death WARNING Indicates a hazard which if not avoided could result in serious injury CAUTION Indicates a hazard whic...

Page 4: ...in any doubt contact your dealer 1 15 If you think you have or someone around you has been affected by carbon monoxide poisoning 1 16 Get them fresh air immediately by leaving the affected area or by opening doors and windows If safe and practical to do so make sure that the machine is turned off DO NOT enter a room you suspect of having carbon monoxide present instead call the emergency services ...

Page 5: ... connectors for the following 1 44 Are intact and have no signs of damage to include but not limited to bare wires chaffing cuts and loose wiring 1 45 If there are any signs of damage the damage item MUST be taken out of service until the damage has been repaired by an electrically competent person 1 46 All trailing cables should be routed so as not to cause any kind of trip hazard 1 47 NEVER work...

Page 6: ...ory tissue death 1 62 Not all factors that lead to white finger disease are known but cold weather smoking and other diseases that affect blood vessels and blood circulation as well as large and long lasting impact of shocks are considered factors in the formation of white finger Note the following to reduce the risk of white finger and carpal tunnel syndrome 1 63 Wear gloves and keep your hands w...

Page 7: ...use the engine to overheat 1 84 Avoid operating the engine with a dust cover 1 85 When the oil falls below the lower level the engine will stop automatically 1 86 Unless you refill with oil the engine will not start again 1 87 The engine start switch controls the ignition 1 88 In the OFF position the ignition circuit is switched off and the engine will not run 1 89 In the ON position the engine is...

Page 8: ... the engine oil make sure the generator is put on stable level ground 2 6 Remove the oil filler cap and check engine oil level 2 7 If the oil level is below the lower level line refill with 15w40 oil to the upper level N B do not screw the filler cap on when checking oil level 2 8 Change contaminated oil 2 9 Oil capacity Model Number Capacity HY8500 1100ml HY10000 1100ml HY220DC 1100ml 2 10 Earthi...

Page 9: ...bol on it 2 15 If the generator is to be used in a more permanent location then it is advisable to connect the generator to an earth road or earth point DO NOT put an earth rod into the ground until you have checked that it is safe to do so We strongly suggest that you contact a qualified electrician to assist you ...

Page 10: ...lever 4 Fuel tap 5 Recoil starter 6 230V 16A socket 7 Engine switch 8 Oil drain plug 9 Oil filler dipstick 10 115V 16A sockets 11 Spark plug 12 Oil filler dipstick 13 Voltage selector 14 Exhaust 2 PART LOCATIONS 2 1 6 9 7 3 10 12 13 14 8 5 11 4 ...

Page 11: ...nly No additives are required 3 2 Clean the area around the fuel filler cap to ensure no dirt or debris enters the fuel system during refuelling 3 2 Remove the fuel filler cap 1 3 3 Pour the fuel carefully through the filter screen in the filler neck 2 3 4 DO NOT over fill the fuel tank fill to the level indicated by the red fill mark on the filter screen 3 3 5 Replace the fuel filler cap and ensu...

Page 12: ... oil filler 3 11 Unscrew and remove the oil filler cap dipstick 3 12 Slowly fill the engine with oil through the oil filler until it reaches the upper thread of the filler hole or to the FULL mark on the dipstick 3 13 Stop filling occasionally to check the oil level 3 14 Refit the oil filler cap and make sure the cap is tightened 3 15 You MUST check the engine oil level before starting every sessi...

Page 13: ...E This procedure is not required if the engine is already warm 4 3 Pull the recoil starter handle 1 slowly until resistance is felt and then pull the handle up swiftly 4 4 After starting allow the recoil starter handle to return to its original position while still holding the handle 4 5 Allow the engine to warm up 4 6 Turn the choke lever back to the RUN 2 position 4 7 Continue to allow the engin...

Page 14: ... the generators wattage capacity 5 2 The rated wattage of lights can be taken from the light bulbs The rated wattage of tools appliances and motors can usually be found on the data label or decal affixed to the devices If the appliance tool or motor does not give wattage multiply volts by ampere rating to determine watts volts x amps watts 5 3 Some electrical induction motors require about three t...

Page 15: ...ments 6 0 Periodic Maintenance MAINTENANCE SCHEDULE After first 10 hours of use Change the engine oil use SAE15W40 Before every use Check oil level Check fuel level Check for leaks damage or loose fittings Clean the machine Every 20 hours or Monthly Change engine oil Clean the Air Filter Every 50 hours or 3 Months Check the Spark Plug Every 100 hours or 6 Months Check the Fuel Filter Check the Exh...

Page 16: ... a sealed container to your local recycling centre for reclamation DO NOT throw waste oil on to the ground or down drains 6 2 Place the generator on a level firm surface and warm up the engine for several minutes Then stop the engine 6 3 Remove the oil filler dipstick cap 6 4 Place an oil pan under the engine 6 5 Remove the oil drain plug so that the oil can be completely drained 6 6 Check the oil...

Page 17: ...gine 6 11 Unscrew the wing nut and remove the air filter cover 1 6 12 Unscrew and remove the foam air filter element from the housing 2 6 13 If there is light dust on the filter it can be blown clean with an airline 6 14 Ideally the air filter should be replaced if dirty 6 15 To reinstall reverse the process 6 20 Spark plug replacement 6 21 CAUTION Allow the engine and spark plug to cool down befo...

Page 18: ... Used Plug a turn 6 40 Fuel tank filter 6 41 Remove fuel filler cap 6 42 Remove the fuel filter and clean 6 43 Wipe off and dry with a clean lint free cloth 6 44 Replace fuel filter in to the fuel tank filler neck 6 50 Exhaust WARNING The exhaust becomes very hot during operation and remains hot for a while after use Allow the exhaust to cool before carrying out any maintenance 6 51 Make sure the ...

Page 19: ...r has fuel No or poor spark Spark plug dirty Clean spark plug Damaged spark plug Replace spark plug Faulty magneto Consult dealer Correct spark Improperly adjusted carburetor Insufficient pulling speed on recoil starting Pull recoil starting rope faster Incorrect fuel Check and replace fuel as required Overloading Check and correct loading Overheating Check and correct cooling system 7 1 Generator...

Page 20: ...vent hard starting Less than 1 month No preparation required 1 to 2 months Fill with fresh fuel 2 months to 1 year Fill with fresh fuel Drain the carburetor float bowl 1 year or longer Drain the fuel tank Drain the carburetor float bowl Pour 5ml of oil down the cylinder bore Fill with fresh fuel Use fuel conditioners that are formulated to extend storage life 8 5 Remove the spark plug and pour a t...

Page 21: ... Sound level 7m 79 95Lwa 79 95Lwa 79 95Lwa Battery Ah 12v 14aH 12V 14Ah 12V 14Ah Engine IC425 E IC460 IC425 E Engine type OHV OHV OHV Power hp 15 17 5 15 Start Recoil Recoil Recoil Displacement 420 459 420 Oil capacity L 1 1 1 1 1 1 Alternator E1C10M I E1C10M L E1C10M L Power kVA 7 8 5 Power factor 1 1 1 Execution Brushless Brushless Brushless Regulation type Capacitor Capacitor Capacitor Dimensio...

Page 22: ...onforms to the following CE directives 12 1 1 2006 42 EC Machinery Directive 12 1 2 2004 108 ECEMC Directive 12 1 3 2000 14 EC Noise Emissions Directive 12 1 4 97 68 ECNRMM Emissions Directive 12 1 5 2006 95 EC Low Voltage Directive 10 DECLARATION OF CONFORMITY ...

Page 23: ...ss Genpower Limited Isaac Way Pembroke Dock Pembrokeshire SA72 4RW UK Telephone contact number Office 44 0 1646 687880 Email contact aftersales genpower co uk Website www hyundaipowerequipment co uk 11 CONTACT DETAILS ...

Page 24: ...24 ...