23
4.1 STARTING YOUR GENERATOR
WARNING!
BEFORE USING THE GENERATOR, A GROUND WIRE MUST BE CONNECTED
TO THE GROUND TERMINAL. THE TERMINAL IS LOCATED ON THE FRONT
PANEL. BEFORE USING THE GROUND TERMINAL CONSULT A QUALIFIED
ELECTRICIAN.
NOTE
Before starting the engine, disconnect all devices from the outlets on
the front panel.
Return the starter grip slowly by hand, do not let it snap back.
Do not push the choke knob to the START/CLOSED position when the
engine is hot or ambient air temperature is high.
4.1.1 MANUAL RECOIL START
1.
Rotate the fuel valve to the OPEN position.
2.
If the engine is cold push the choke lever to the START/CLOSED position.
The choke is used to provide the proper air-fuel mixture when the engine is
cold. You can find the choke beside the air filter on the left side.
3.
Disconnect all devices from the front panel.
4.
Turn the power switch to the ON position.
5.
Pull the starter slowly until it engages then pull quickly. Repeat until the
(HG1500)
Empty
Full
1
2
3
4
5
6
OPEN
START
RUN
Summary of Contents for HG10