Electrical instant water heater
13.
Electrical instant water heater
EN
EN
Incoming water is heated inside the heating ask, when it ows through the heating element.
Water temperature in the water supply network may uctuate throughout the year from +3°C
to +20°C. Therefore, water ow in winter shall be made lower than in summer to obtain the
optimum water temperature. Water ow is controlled by the valve at the water inlet of the water
heater. Never install an isolation valve or shut o water ow at the water heater outlet. A er
activation of heating, wait for 10-20 sec until temperature of heated water is stabilized.
For adjustment of hot water temperature, use the valve at the inlet connection (cold water inlet).
When you decrease inlet ow rate of water, you increase outlet temperature of water and vice
versa. For water heaters of H-IWR1-5P and H-IWR1-6P series, you can also place the On/O /
power control knob to the low power position ( ) or to the medium power position ( ) in or-
der to adjust water temperature. To switch o the water heater, place the On/O /power control
knob to the OFF position ( ), close the cold water feed valve at the inlet, and de-energize the
water heater.
CLEANING
Operation of the water heater may result in scaling of the shower/tap nozzle openings. This
reduces e ciency of heating, deteriorates water spraying, and increases water pressure in the
heating ask.
For prevention of such phenomena, periodically clean the nozzle using household chemical
agents and so brushes. Do not use abrasive cleaning substances and inappropriate chemical
agents.
Prior to cleaning the outer surfaces, disconnect the water heater from the electrical mains and
allow it to fully cool down. Clean the outer surface of the appliance housing with a slightly moist-
ened so cloth and then wipe it dry. Do not use abrasive cleansers for cleaning.
If water ow rate from the water heater decreases, clean the coarse lter (rubber gasket and
strainer) installed at the cold water inlet of the water heater. For that, disconnect the appliance
from the electrical mains and allow it to fully cool down. Then, shut o cold water feeding,
unscrew the cold water supply pipe from the water heater, remove the rubber gasket with the
strainer, and ush it under a jet of owing water. Restore the inlet connection in the reverse
sequence.
1 - O position
2 - On/O and power control knob
3 - Low power position
4 - Medium power position
5 - Full power position
Before rst start or a er a long idle period of the water heater, ll it with water opening the cold
water feed isolation valve and make sure that cold water steadily ows from the water outlet at
the consumption point. A er that, switch on the appliance and make sure that the power indica
-
tor on the front panel lights up*.
To switch on heating, place the control knob to the ON position ( ). If su cient water ow and
pressure at least 0.08 MPa are available, the water heater will start heating water.
* For connection to the electrical mains, this series of water heaters is complete with a power
cord and a male plug. The power cord has length of 1.5 m and copper conductor section of 3x1.5
mm2.
Never use an electrical male plug and socket for connection of the water heater to the electrical
mains, except for H-IWR1-3P series. The water heater shall be connected to the 220 VAC power
supply source permanently with obligatory connection to the electrical grounding loop. Make
sure that resistance of the grounding loop is < 4 . The electrical cable is led into the water
heater through its rear wall and connected to the terminal block according to marks on the rear
panel, where - ground conductor, L - phase conductor, N - neutral conductor. To lead in and
connect the electrical cable, remove the appliance front panel. For that, unscrew the securing
screw in its upper part. A er connection of the electrical cable to the terminal block, make sure
that all clamping screws of the terminal block are secured. Secure the cable inside the heater
using a clamping plate, place back the front panel, and turn in the securing screw in the upper
part of the appliance.
OPERATION
* The service life of the power indicator is 3000 hours continuously. Therefore, disconnect the appliance from the
electrical mains a er use to extend the power indicator life.
H-IWR1-3P*
H-IWR1-5P
H-IWR1-6P
3500
5500
6500
1,5
2,5
4,0
Appliance series
Power, W
Copper
conductor
section,
min, mm
2
Circuit breaker,
min, A
OFF
O
N
5
3
4
2
1
16
25
32
CAUTION!
Refer to «Water heater safe operation and installation rules».
Summary of Contents for H-IWR1-3P-UI056/C
Page 12: ...22 23 RU RU 0 220 50 H IWR1 3P 35...
Page 13: ...24 25 RU RU 10 0 3 2 0 07 0 6 0 6 0 6 450 12 G1 2 220 130mm 130mm...
Page 15: ...28 29 RU RU 1 2 3 85 4 5 1 2 1 2 1 2 3 85 4 5 1 2 1 2...
Page 16: ...30 31 RU RU Hyundai www btpart ru www h hvac ru...
Page 19: ...36 37 RU RU ID 171 21 12 2004 18 5 Hyundai ID ID Hyundai...
Page 20: ...38 39 RU RU www hc hvac ru www hc hvac ru 1 0 5 1 1 0 5 1...
Page 21: ...40 41 RU RU 5 0 5 1 0 5 1 1 1 2 3...
Page 23: ...44 RU 25 502 11 19 01 1998 55 1 45 2 3 10 4 5 44...
Page 24: ...A...
Page 25: ...A Hyundai...
Page 28: ...54 55 RU RU...
Page 29: ...www hyundai hvac com Licensed by Hyundai Corporation Korea...