Disposal

Upon expiration of service life, the water heater shall be disposed. For more details regarding 
disposal of the water heater, please contact a representative of the local authorities.

Service life is around 10 years. The notion of the service life of the device is not equal to the 
warranty period.

INSTALLATION

                      CAUTION! 

                                           Refer to «Water heater safe operation and installation rules».

During installation of the water heater, rigorously observe the laws, regulations, directives, and 

standards (safety requirements, disposal rules/procedure, electrical safety rules, etc.) e ective in 

your country, as well as directives of local electrical energy/water suppliers.

Mounting

During selection of a location for the water heater, it is necessary to ensure free access to it 
on the basis of not less than 0.3 m from above, from below, and sideways. This will ensure the 

maximum comfort for maintenance and adjustment of the water heater, when necessary. A er 

you have selected the place for installation of the water heater, mark points for mounting screw 
holes. Drill two holes to appropriate depth in the wall using a drill with suitable size for the dowel 
pins and screws provided in the water heater package. Insert the dowel pins into the wall holes 
and turn in the mounting screws. Do not turn in the screws fully. There shall be a gap between 
the screw heads and wall necessary to hang up and secure the water heater. Hang up the water 
heater onto the screws and check security of mounting. The appliance shall be installed on the 
wall strictly horizontally with its connections downward. For more secure mounting, you can use 
the through hole in the lower part of the rear panel (refer to “Overall and installation dimen-
sions”) to turn in an additional screw through it to the wall.

Water supply network connection

The water heater is directly connected to the cold water supply network with operating pressure 
from 0.07 MPa to 0.6 MPa. If water pressure in the water supply network exceeds 0.6 MPa, 
install a reduction valve (pressure reducer) in the feed system so that operating pressure does 

not exceed 0.6 MPa. Prior to connecting the water heater,  ush the cold water supply pipe with 

owing water.

If water hardness in the water supply main exceeds 450 mg/l (CaCO3), we recommend you to use 

a separate water  lter upstream of the water heater inlet to extend service life of the heating 

element.

Connect the cold water supply pipe to the cold water inlet marked with blue color. Install the 
rubber gasket and strainer provided in the package between the pipe and connection. The con

nection has male thread 12 mm in diameter (G1/2”). Connect the accessories provided in the 
package to the heated water outlet marked with red color (refer to “Accessories” and version of 
your water heater). The cold water feed isolation valve shall be installed upstream of the water 

heater inlet. Never install an isolation valve at the heated water outlet of the water heater. Pass 
water  ow through the water heater to make sure that it is operable. Check tightness of all 

connections and retighten them as necessary.

Electrical mains connection

Connect the water heater to the 220 VAC electrical mains with a three-conductor copper electri

-

cal cable having minimum conductor section and a circuit breaker in the power switchboard as 
indicated in the table below:

Correct connection

Valve

Inlet

Outlet

130 mm

130 

mm

Summary of Contents for H-IWR1-3P-UI056/C

Page 1: ...water heater Instruction manual Warranty card Models EN H IWR1 3P UI056 C H IWR1 3P UI057 S H IWR1 3P UI058 CS H IWR1 5P UI059 C H IWR1 5P UI060 S H IWR1 5P UI061 CS H IWR1 6P UI062 C H IWR1 6P UI063...

Page 2: ...approved The manufacturer is not responsible for any spelling mistakes in the text and incorrect interpretation of the instruction manual content GENERAL Description Electrical instant water heaters a...

Page 3: ...nstruction manual 4 Crane 5 Mounting screws 6 Dowel pins Version S 1 Front panel 2 Power indicator 3 On O and power control knob 4 Hot water outlet 5 Cold water inlet 6 Rear panel 7 Mounting screw hol...

Page 4: ...35 153x248x95 5500 220 25 50 3 2200 3300 5500 IPX4 I 0 0 07 0 6 3 6 85 0 35 153x248x95 6500 220 30 50 3 3000 3500 6500 IPX4 I 0 0 07 0 6 4 2 85 0 35 153x248x95 Appliance series H IWR1 3P H IWR1 5P H I...

Page 5: ...sing a male plug except for H IWR1 3P series Never use any electrical extension cords Cross section of the electrical cable used for connection to the electrical mains shall meet rated current of the...

Page 6: ...ith its connections downward For more secure mounting you can use the through hole in the lower part of the rear panel refer to Overall and installation dimen sions to turn in an additional screw thro...

Page 7: ...upply pipe from the water heater remove the rubber gasket with the strainer and ush it under a jet of owing water Restore the inlet connection in the reverse sequence 1 O position 2 On O and power con...

Page 8: ...ve is not opened Problem with tightness of connections 1 Unstable water pressure 2 Water temperature at the outlet from the water heater is too high causing repeated tripping of the overheating protec...

Page 9: ...16 17 RU RU 17 17 17 18 18 19 21 21 22 22 22 22 23 24 24 24 25 25 26 27 28 29 32 Hyundai www hyundai hvac com Hyundai Hyundai Rainforest...

Page 10: ...I056 C H IWR1 3P UI056 C H IWR1 3P UI056 C H IWR1 3P UI056 C H IWR1 3P UI056 C H IWR1 3P UI056 C H IWR1 3P UI056 C H IWR1 3P UI056 C RU Electrical instant water heater Instruction manual Warranty card...

Page 11: ...0 6 4 2 85 0 35 153 248 95 H IWR1 3P H IWR1 5P H IWR1 6P H IWR1 3P 3 5 16 18 1 5 248 150 42 5 95 130 102 136 4 153 7 118 3 RU Electrical instant water heater Instruction manual Warranty card EN H IWR1...

Page 12: ...22 23 RU RU 0 220 50 H IWR1 3P 35...

Page 13: ...24 25 RU RU 10 0 3 2 0 07 0 6 0 6 0 6 450 12 G1 2 220 130mm 130mm...

Page 14: ...26 27 RU RU 1 5 3 1 5 2 H IWR1 3P 220 4 L N 3000 H IWR1 3P H IWR1 5P H IWR1 6P 3500 5500 6500 1 5 2 5 4 0 16 25 32 2 OFF O N 5 3 4 2 1 3 20 10 20 H IWR1 5P H IWR1 6P 1 2 3 4 5 0 08...

Page 15: ...28 29 RU RU 1 2 3 85 4 5 1 2 1 2 1 2 3 85 4 5 1 2 1 2...

Page 16: ...30 31 RU RU Hyundai www btpart ru www h hvac ru...

Page 17: ...33 RU RU 44 2014 Hyundai Hyundai Hyundai 45 Hyundai Hyundai Hyundai www hc hvac ru 7 495 627 5285 www hc hvac ru service hc hvac ru Hyundai Hyundai Hyundai 20 10 7 8...

Page 18: ...34 35 RU RU Hyundai 42 44 3 10 3 5 www hc hvac ru Hyundai ID 42 c ID www hc hvac ru Hyundai Hyundai...

Page 19: ...36 37 RU RU ID 171 21 12 2004 18 5 Hyundai ID ID Hyundai...

Page 20: ...38 39 RU RU www hc hvac ru www hc hvac ru 1 0 5 1 1 0 5 1...

Page 21: ...40 41 RU RU 5 0 5 1 0 5 1 1 1 2 3...

Page 22: ...42 43 RU RU C 01 01 2014 ID 1 2 1 30 2 5 30 2 3 3 3 3 1 2 1 3 5 45 Hyundai Hyundai Hyundai Hyundai www hc hvac ru Hyundai UNIT CODE PRODUCTION ID SERIAL NUMBER 40...

Page 23: ...44 RU 25 502 11 19 01 1998 55 1 45 2 3 10 4 5 44...

Page 24: ...A...

Page 25: ...A Hyundai...

Page 26: ...12 2 service hc hvac ru kz service hyundai hvac com by service hyundai hvac com c 495 710 71 72 627 52 85 Hyundai www hc hvac ru Hyundai 7 495 627 5285 Hyundai Hyundai 7 495 627 5285 service hc hvac r...

Page 27: ...52 53 RU RU Ask distributor of your region for Warranty Coupon of a product Pida la garant a al distribuidor en su pa s KO EN ES KZ BY...

Page 28: ...54 55 RU RU...

Page 29: ...www hyundai hvac com Licensed by Hyundai Corporation Korea...

Reviews: