AUTOMATIC TRANSAXLE OIL COOLER FLUSHING

 

 

TSB #: 

18-AT-008

 

Page 3 of 4 

 

 

SERVICE PROCEDURE 

1.  Mark the hoses with tape or parts tags so they 

can be reconnected correctly.  
 
Disconnect the oil cooler inlet and outlet hoses 
from the oil cooler tubes.

 

 

2.  Insert the nozzle of the aerosol can to either 

hose and secure it with a hose clamp. Position 
the other hose so that it discharges into a waste 
container. 
 
Remove the protective cap. Hold the can 
upright and press firmly on the button to release 
the solution. Flush for 15-20 seconds until clear 
liquid comes from the outlet hose. 

 

 

 

3.  Reverse the hoses and flush in the other 

direction until clear liquid comes from the outlet 
hose. For best results, use the entire contents 
of the aerosol can. 
 
 

 

 

 

 Clear liquid must flow freely in both 
directions through the ATF cooler. If 
not, the ATF cooler is clogged with 
debris and must be replaced.

 

NOTICE

 

 

 The procedure is the same for both 
ATF coolers.

 

NOTICE

 