Problem 

Possible Cause 

Possible Solution 

Pump will not start 

No mains power 

Turn on mains power 

Fuse blown 

Inspect and replace fuse 

Internal thermal cut out has not 
reset 

Leave 5 to 10 minutes and try 
again 

Extension cord faulty 

Replace extension cord 

Impeller jammed 

Disconnect from the mains 
power supply and remove the 
impeller obstruction 

Float switch stuck against 
obstruction 

Remove the obstruction 

Pump starts but will not pump 

Blocked inlet 

Check the inlet and remove 
obstruction 

Blocked outlet 

Check the outlet and remove 
obstruction 

Exceeded maximum pump 
head 

Check the specifications for 
maximum head 

Air trapped inside the pump 

Remove and reinsert the pump 
at an angle to remove trapped 
air 

Impeller may be damaged 

Consult your dealer 

Pump will not stop 

Float switch prevented from 
moving to fully down position 

Remove obstruction 

Faulty float switch 

Consult your dealer 

Pump stops running 

Thermal overload 

Turn the pump off and leave for 
5 to 10 minutes 

Pump has run dry 

Submerge the pump 

Impeller jammed 

Turn off the pump and remove 
the obstruction 

5. TROUBLESHOOTING

Summary of Contents for HYSP850D

Page 1: ...1...

Page 2: ...7 2 PART LOCATIONS 8 3 OPERATING INSTRUCTIONS 9 10 4 MAINTENANCE 10 5 TROUBLESHOOTING 11 6 SPECIFICATION 12 7 DECLARATION OF CONFORMITY 13 8 PRODUCT DISPOSAL RECYCLING 14 9 CONTAT DETAILS 15 10 WARRAN...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...ormity 1 80 General Machine Safety 1 81 Do not use the pump if damaged 1 82 You must always inspect the pump cables and plug for damage before use 1 83 Disconnect the pump from the mains power supply...

Page 8: ...8 1 Carrying Handle 2 Pump Body 3 Pump Outlet 4 Pump Base 5 Float Switch 6 Float Switch Level Clip 2 PART LOCATIONS...

Page 9: ...diameter will affect the maximum flow rate 3 3 Adjust the depth of the float switch to the desired depth by clipping the float switch cable into the float switch depth clip at the desired level 3 4 I...

Page 10: ...ins and float switch cable for wear or damage 4 2 Remove any obstructions from the base of the pump and impeller 4 3 Rinse the exterior of the pump with clean water 4 4 Remove stubborn contamination w...

Page 11: ...ked inlet Check the inlet and remove obstruction Blocked outlet Check the outlet and remove obstruction Exceeded maximum pump head Check the specifications for maximum head Air trapped inside the pump...

Page 12: ...850D Voltage v 230v 50Hz Power w 850 Max Flow Rate l h 17500 Head m 10 Max Depth m 7 Outlet Hose Size Inlet Diameter 33 40 50 60mm Max Solid Diameter mm 35 Max Water Temperature C 35 Weight kg 6 5 6 S...

Page 13: ...Pump Net installed power 850w The technical documentation is kept by Roland Llewellin Genpower Ltd Isaac Way Pembroke Dock Pembrokeshire SA72 4RW The conformity assessment procedure followed was in ac...

Page 14: ...uthority or recycling centre 8 4 Certain products contain batteries which should not be disposed of in your domestic waste 8 5 You MUST recycle batteries which should not be disposed of in your domest...

Page 15: ...re constantly being reviewed and updated However if you find an error omission or something you find unclear please contact your dealer for assistance 11 1 Our latest manuals are also placed online 9...

Page 16: ...mbroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom...

Reviews: