OIL WARNING SYSTEM
When the oil level falls below the lower level, the engine stops
automatically. Unless you refill with oil, the engine will not start again.
ENGINE SWITCH
The engine switch controls the ignition system.
①
RUN
Ignition circuit is switched on. The engine can be started.
②
STOP
Ignition circuit is switched off. The engine will not run.
③
START
Starting circuit is switched on. The starter motor starts.
ECONOMY CONTROL SWITCH
When the economy control switch is turned ON, the economy control
unit control the engine speed according to the connected load. The
results are better fuel connection and less noise.
DC CIRCUIT PROTECTOR
The DC circuit protector turns off automatically when the load exceeds
the generator rated output.
CAUTION:
Reduce the load to within specified generator rated output if the DC
circuit protector turn off.
OUTPUT RESET
Push reset button for continuous 2 seconds, the generator will recover
the AC output when the generator stop AC output under overload
protect.
NOTE:
Please reduce the load of generator to ensure that the total load is within
the rated power.