![Hyundai power products HY6500SEi User Manual Download Page 10](http://html1.mh-extra.com/html/hyundai-power-products/hy6500sei/hy6500sei_user-manual_2197905010.webp)
USING ELECTRIC POWER
1. AC APPLICATION
(a)
Check the AC pilot lamp for proper voltage.
(b)
Turn off the switch(es) of the electrical appliance(s) before
connecting to the generator.
(c)
Insert the plug(s) of the electrical appliance(s) into the receptacle.
CAUTION:
Be sure the electric apparatus is turned off before plugging in.
Be sure the total load is within generator rated output.
Be sure the socket load current is within socket rated current.
The economy control switch must be turned to OFF when using
electric devices that require a large starting current, such as a
compressor or a submergible pump.
2
.
OVERLOAD INDICATOR LIGHT
The overload indicator light comes on when an overload of a connected
electrical device is detected, the inverter unit overheats, or the AC output
voltage rises. The electronic breaker will then activate, stopping power to
the generation in order to protect the generator and any connected
electric devices. The overload indicator light (red) will turn on, then the
generator will stop output. If so please follow the following steps:
(a)
Turn off any connected electric devices
(b)
Reduce the total wattage of connected electric devices within the
application range.
(c)
Check for blockages in the cooling air inlet and around the control
unit. If any blockages are found, remove.
(d)
After checking, push output reset.
CAUTION:
The generator AC output automatically resets when the engine is stopped and then restarted.
The overload indicator light may come on for a few seconds at first when using electric devices that require a large
starting current, such as a compressor or a submergible pump. However, this is not a malfunction.
OFF
ECON. SW
RESET
9