Hytronik SensorDIM HEC7030 Manual Download Page 7

Current

350mA

500mA

550mA

700mA

750mA

900mA

1 2

3

EXT.

EXT.

LED +
LED -

LED +
LED -

LED +
LED -

LED +
LED -

N

L

Push

EXT.

EXT.

N

L

Push

EXT.

EXT.

N

L

Push

Maximum10pcs

LED Driver Specification

Wiring Diagram_Push

Wiring Diagra EXT.

Switch-Dim.

Switch-Dim.

N

N

LED Current Selections

1

The current can be easily configured by 
choosing the correct combination of the 
DIP switches (see table on the left). 

30%

10%

9

I

II

I – 10%
II – 30%

5

   Stand-by dimming level

The setting is used to select the desired dimmed light level used in 
periods of absence for enhanced comfort and safety.

I –  0s
II – 10s
III – 30min
IV –  ∞

+

4

   Stand-by period (corridor function)

This is the time period you would like to keep at the low light output level 
before it is completely switched off in the long absence of people.

8

Note: “0s” means on/off control;
         “+    ”means the stand-by period is infinite and the light is effectively 
         controlled by the daylight sensor, off when natural light is sufficient 
         and automatically on at dimming level when insufficient.

0s

10s

30min

8

7

I

II

III
IV

+

Subject to change without notice.

Edition: 26 Feb. 2020      Ver. A0      Page 7/8

Summary of Contents for SensorDIM HEC7030

Page 1: ...tant current LED driver 2 in 1 Suitable for building into the fixture for Office Commercial Lighting Classroom Meeting Room Use for retrofit and new luminaire designs installations Features IP20 RED E...

Page 2: ...hed sensor antenna SAM5 it requires very little space on the LED panel Only the antenna is installed on the PCB surface while the main body can be hidden behind the panel Completely shadow free Main B...

Page 3: ...ion 5 17 40 2 21 10 Settings on this demonstration Hold time 10min Daylight threshold 50lux Stand by dimming level 10 Stand by period Check Hold time ends Power On Dim 100 On Off motion No motion Now...

Page 4: ...riggered ON by motion until the expiration of pre set hold time After this period the sensor goes back to normal sensor mode Off On the light turns on and goes to sensor mode no matter if ambient Lux...

Page 5: ...es Ambient daylight threshold Lux Disable Manual override Semi auto mode absence detection M A Lux disable Press this button the built in daylight sensor stops working and all motion detected could tu...

Page 6: ...ch specific application 1 2 Note by choosing Sensor OFF it becomes an ordinary driver without occupancy detection I 5s II 30s III 3min IV 10min 2 Hold Time Select the DIP switch configuration for the...

Page 7: ...ting is used to select the desired dimmed light level used in periods of absence for enhanced comfort and safety I 0s II 10s III 30min IV 4 Stand by period corridor function This is the time period yo...

Page 8: ...nt currents LED Maximum Load and Voltage 2 Subject to change without notice Edition 26 Feb 2020 Ver A0 Page 8 8 Additional Information Documents 1 Regarding precautions for microwave sensor installati...

Reviews: