background image

Ceiling mounted detection pattern (m)

Ceiling mounted height(m)

6

0

12

10%

10%

30%

30%

75%

75%

50%

50%

5. Wiring Diagram

8. Trouble Shooting

Description of the 
Button Functions 
(remote control HRC-11)

MALFUNCTION CAUSE REMEDY

CAUSE

REMEDY

The fixture does not light up

The fixture is always on

Check detection area setting

The fixture is on when it should not

Incorrect daylight threshold setting

Continued movement in the detection zone 

Sudden change in temperature due to weather (wind, rain, snow) or air 
expelled from fans, open windows

Detection zone not targeted

Faulty fixture

No power supply

Adjust daylight threshold setting

Replace fixture

Check power to sensor

Check detection area setting

Adjust zone, change installation site

7. 

HRC-11

6

8

10

11

12

13

14

2

4

1

3

7

9

5

Permanent ON/OFF [               ]

Press button      to select permanent ON or permanent OFF mode.
 * Press button     /     to resume automatic operation. 

Semi-auto Mode [ button     &     ]

Power output [ button 

   

 ]

Press button     , the light output shifts between 80% and 100%.
Note: the function of “Sensor off” and “Twilight” are disabled.          

Ambient daylight threshold [ button 

    

 ]

Detection range [ zone     ] 

Press buttons in zone 

   

  to set detection range at 100% / 75% / 

50% / 10%.

Stand-by time [ zone     ]

Press buttons in zone     to set the stand-by period at 0s / 10s / 
1min / 5min / 10min / 30min / 1h / +∞. 
Note: “0s” means on/off control; “+∞” means bi-level control, 100% 
on when motion detected, and remains at the stand-by dimming 
level when no presence after hold-time.

Daylight threshold [ zone 

   

  ]          

Press buttons in zone     to set the daylight sensor at 2Lux / 10Lux / 
50Lux / 100Lux / 300Lux / 500Lux or Disable.
Note:  To set daylight sensor at 100Lux / 300 Lux / 500Lux, press 
         button     Shift at first.

button 

Auto Mode [ button     ]

Brig/- [ button     ]

Press button     to adjust the light brightness between 10% ~ 100%. 

Scene prog. [ zone      ] (One-key-commissioning)

1. Press button     Shift, the red LED is on for indication. 
2. Press button 

    

, the ambient lux level is sampled and set as the 

    new daylight threshold.

Hold time [ zone     ]

Press buttons in zone     to set the hold time at 2s / 30s / 1min / 
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button 
                Shift at first.
         2. 2s is for test purpose only, stand-by period and daylight     
             sensor settings are disabled in this mode.
*To exit from Test mode, press button     or any button in zone     .    

Stand-by dimming level [ zone      ]

Press buttons in zone     to set the stand-by dimming level at 10% / 
20% / 30% / 50%.

 Dual tech & RF mode [ zone     ]

 All buttons in zone      are disabled. 

Detection Pattern

6. 

Shift [ button 

    

 ]

RESET [ button     ]

Press button     , all settings go back to the rotary switch settings.

Press button     to initiate automatic mode. The sensor starts working
and all settings remain as before the light was switched ON/OFF.

1. Press button “Start” to program.
2. Select the buttons in      “Detection range”,     /     “Daylight threshold”, 
        “Hold time”,      “Stand-by time”,      “Stand-by dimming level” to   
    set all parameters.
3. Press button “Memory” to save all the settings programmed in the 
    remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).     
    For example, to pre-set detection range 100%, daylight threshold
    Disable, hold time 5min, stand-by time +∞, stand-by dimming level 
    30%, steps should be:
    Press button     Start, button     100%,     Disable,     Shift,     5min,        
         Shift,     +∞ ,     30%,     Memory. By pointing to the sensor unit(s)   
    and pressing      Apply, all settings are passed on the sensor(s).

Press button     , the LED on the top left corner is on for indication.    
All values / settings in RED are in valid for 20 seconds. 

1. Press button     Shift (the red LED is on for indication), 
2. press button     to initiate semi-auto mode. The fixture is manually on 
    by push-switch and automatically off in semi-auto mode.

1

8

3

3

2

9

10

11

12

13

14

14

13

12

11

11

10

9

8

2

2

3

3

3

3

4

4

4

5

6

7

7

7

7

3

3

8

8

9

10

10

11

13

12

11

12

13

6

5

4

1

2

4

3

HMW15-20170308-A1

L
N

SY

NC

SY

NC

P

DALI

L

N
+

+

LED Driver

-

 -

L

N LED Driver

+

-

N L

SY

NC

SY

NC

P

DALI

+

-

N L

DALI

LED

HMW15

HMW15

+

 - DALI

+

-

LED

Hytronik Industrial Ltd.  |  www.hytronik.com

3rd Floor, block C, complex building, 155#, Bai'gang road south, 

Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023

Tel: 86-752-2772020   Fax: 86-752-2777877  

Note: if neither function 4.3 nor 4.4 is desired, simply leave the “push” terminal disconnected.

All manuals and user guides at all-guides.com

Reviews: