1. Technical Specifications
Product type RF wireless dual sense independent DALI sensor (tri-level control)
Operating voltage 220-240VAC 50/60Hz
Rated load Maximum 20pcs DALI devices, Maximum 40mA
Power consumption < 1.5W
Detection angle 360
o
Detection area (Max.)*
Detection range 10% / 50% / 75% / 100%
Hold time 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min
Stand-by time 0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞
Stand-by dimming level 10% / 20% / 30% / 50%
Daylight threshold 2 ~ 500Lux, Disable
RF transmission distance 30 meters in the open area
RF frequency 868MHz (FSK mode)
Warming up time 30s
Operating temperature -20
o
C ~ +50
o
C
IP rating IP65
Sensor mode HF, PIR, HF+PIR, HF / PIR
3. Rotary Switch for RF grouping
4. Functions
The built-in daylight sensor can read ambient natural light and switch off the fixture automatically
whenever artificial light is not required (natural light lux level exceeds daylight threshold).
Note: if the stand-by time is preset at "+∞", the fixture never switches off even when natural light
is sufficient.
4.2 Lux Off Function
Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas it requires
a light change notice before switch-off.
It offers 3 levels of light: 100%-->dimmed light-->off; and 2 periods of selectable waiting time: motion
hold-time and stand-by period; Selectable daylight threshold and freedom of detection area.
4.1 Tri-level Control (Corridor Function)
2. Installation
Warnings:
1. Installation must be carried out by a qualified engineer in accordance with
local regulations.
2. Disconnect power supply before installing.
3. Install to a solid surface - vibrations may cause mis-triggering.
4. Ensure environmental conditions are suitable for electronic equipment
Rotary switch for RF grouping
(Please see the location in 2. Installation)
15 channels are available for fast grouping via rotary switch. By simply selecting the same channel on each
unit, the grouping is automatically completed.
Noted: channel "0" is not for fast grouping, and sensors can only be grouped by remote control.
The light will flash ONCE rapidly after receiving the command from the remote controller.
Note: There is no load indication (the light will not flash) when button ON/OFF, POWER 100% or POWER
80% is pressed.
4.3 Load Indication
Rotary switch
for RF grouping
HC034RF (RF receiver)
RF antenna
Infrared remote receiver
1-10V+
1-10V-
L’
N N L
71.5
4.2
37.5
38.3
25
11.8
78.2
87
Installation hole
Product type RF wireless receiver
Operating voltage 220-240V 50Hz
Rated load Capacitive:400W; Resistive:1200W
IP rating IP20
HC034RF
RF WIRELESS DUAL SENSE SENSOR FOR HIGH BAY HIM39/RF AND HC034RF
Installation and Instruction Manual
TM
HIM39/RF-20190104-A1
A. Ceiling mount
B. Screw to the Luminaire by conduit
C. Attach to the shade by clamp
Sensor module
PIR
LED indicator
Infrared receiver
Rotary switch for RF grouping
Cable entry
Installation rack
Daylight sensor
81.5
4.1
66.6
91.5 80.7 75
4.1
59.3
73.5
57.3 47.5
24.5
Cable entry
Sensor module
PIR
LED indicator
Infrared receiver
Rotary switch for RF grouping
Daylight sensor
59.6
66.6
89.9
0.825”
75
64
43.8
43
59.3
73.5
35.2
57.3 47.5
163.2
33.7
28.5
4.5
15
96.8
66.6
ぶ
4.5
93.8
84.5 59.3
ぶ
29
Sensor module
PIR
LED indicator
Infrared receiver
Rotary switch for RF grouping
Angle adjustment
Luminaire clamp
Daylight sensor
Installation Height : 15m
Detection Range (Ø) :18m