Settings (Remote Control HRC-11)
Press button “ON/OFF” to select permanent ON or permanent OFF mode.
* Press button “AUTO”, “RESET” to quit this mode.
The mode will change to AUTO Mode after power failure.
Permanent ON/OFF function
ON/
OFF
AUTO mode
Press button “AUTO” to initiate automatic mode. The sensor starts working and all
settings remain as before the light is switched ON/OFF.
Press button “Shift”, the LED on the top left corner will flash to indicate mode
selection. All values / settings in RED are valid for 20 seconds.
Shift Button
Press the buttons to select light output at 80% (at initial 10,000
hours) or 100%.
Note: “Sensor off” and “Twilight” functions are disabled.
Power output
Reset Settings
Press button “RESET”, all settings go back to rotary switch settings. Sensor detection
mode returns to DIP switch settings.
Press the buttons to adjust the light brightness to reset the target
lux level.
Brig/-
Scene program -
1-key commissioning
1. Press button “Start” to program.
2. Select the buttons in “Detection range”, “Daylight threshold”, “Hold-time”, “Stand-by time”, “Stand-by dimming level” to set all
parameters.
3. Press button “Memory” to save all the settings programmed in the remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).
For example, to set detection range 100%, daylight threshold Disable, hold-time 5min, stand-by time +∞, stand-by dimming level 30%, the steps should be:
Press button “Start”, button ”100%”, “Disable”, “Shift”, “5min”, “Shift”, “+∞”, “30%”, “Memory”. By pointing to the sensor unit(s) and pressing “Apply”, all
settings are passed on the sensor(s).
Detection range
Press buttons in zone “Detection range” to set HF detection range at 100% / 75% / 50% / 10%.
& A
4
4h
h
h
HRC-11
Press buttons in zone “ Daylight threshold” to set daylight sensor / target lux level at 50Lux / 100Lux / 300Lux / 500Lux / Disable.
Note: 2lux / 10lux are disabled.
To set daylight sensor at 100Lux / 300Lux / 500Lux, press “Shift” button first.
Daylight threshold
1. Press button “Shift”, the red LED starts to flash.
2. Press button “Ambient”, the surrounding lux level is sampled and set as the new daylight threshold / target lux level.
Ambient daylight threshold
Hold-time
Press buttons in zone “hold-time” to set the hold-time at 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min.
Note: 1. To set hold-time at 30s / 5min / 15min / 30min, press “Shift” button first.
2. 2s is for testing purpose only, stand-by period and daylight sensor settings are disabled in this mode.
*To exit from Test mode, press button “RESET” or any button in “Hold-time”.
1. Press button “Shift”, the red LED flashes for indication.
2. Press button “SEMI-AUTO/AUTO” to initiate semi-auto mode. The fixture is
manually turned on by pressing the push-switch, and goes off automatically in this
mode. (Absence detection mode)