background image

Mains voltage

Mains current

Power factor

Operation temperature

Dimming interface 

Abnormal protection

Dimming range

Stand-by power consumption

Over-heat protection

EMC standard

Safety standard

DALI standard

Dielectric strength

IP grade

220~240VAC  50/60Hz 

•

Output voltage ( U-out max.) 

200V

  Ta: -20~+50

     Tc:+80

 

Output short-circuit protection with auto-reset 

1~30% PWM dimming;     30~100%  analogue dimming.

<0.5W

Over-heat protection with auto-reset

EN55015, EN61547, EN61000-3-2/3  

EN61347-1, EN61347-2-13,  EN60598-1    

IEC62386-101,102,207

Input

ĺ

output : 3750VAC  

IP20    

0.3 ~ 0.25A

34W / 225mA / 36 ~ 150V

38W / 250mA / 36 ~ 150V

41W /275mA / 36 ~ 150V

45W / 300mA / 36 ~ 150V

49W / 325mA / 36 ~ 150V

50W / 350mA / 36 ~ 140V

50W / 375mA / 36 ~ 130V

50W / 400mA / 36 ~ 125V

50W / 425mA / 36 ~ 115V

50W / 450mA / 36 ~ 110V

50W / 475mA / 36 ~ 105V

50W / 500mA / 36 ~ 100V

50W / 525mA / 36 ~ 95V
50W / 600mA / 36 ~ 83V

50W / 550mA / 36 ~ 90V

50W / 575mA / 36 ~ 86V

89%

DALI, Switch-Dim., 1-10V

Max. output 

power/current/voltage  

Max. Efficiency

SECTION 4 SPECIFICATION

Step2

The commander unit (master unit)

The beeper beeps one time

Beeper beeps rapidly 
when RF signal is received  

Short press “Transmit” button on RC, the commander unit (master unit) will 
beep one time to send the transmission signal.  

Upon receiving the transmission signal, the receiver unit (slave unit) will 
rapidly beep 3 times in 1s to indicate the success of pairing. Repeat this step 
to pair more units. One more short press on “Learn/Erase” button to the 

UHFHLYHUXQLWWRFRPSOHWHWKHSDLULQJSURFHVVWKHUHFHLYHUXQLWZLOOTXLWWKH

pairing mode. 

Note:
Press button RX100%, the light on receiver unit is 100% on upon receiving 
RF on signal; Press “RX STBY%” button, the light(s) goes to preset stand-by
dimming level directly.

The receiver unit (slave unit)

Short press “Learn/Erase” button on RC to activate pairing mode, and the 
receiver unit will beep once every second for 3min.

Note: the unit can only pair up to 30 units.    

Step1

The receiver unit (slave unit)

Beeper is on for 3min

Short press “Learn
/Erase” button

RF grouping

Short press “Transmit”
button

Step

3

The receiver unit (slave unit)

Beeper is on 

Erase:
Long press “Learn/Erase” button for 3s to the sensor unit. The beeper rapidly 
beeps for about 5s. all commands it has received before will be erased. 

Short press “Transmit”
button

1. HF, PIR, HF+PIR, HF/PIR are disabled.
2. For RF grouping, please see next page.

Dual tech & RF mode [ zone     ]

14

Reviews: