![Hytronik HEC7430 Instruction Manual Download Page 3](http://html1.mh-extra.com/html/hytronik/hec7430/hec7430_instruction-manual_2194896003.webp)
Remote Control HRC-05
Permanent ON/OFF [ ]
1. Press button , to select permanent ON or permanent OFF mode.
2.
3UHVVEXWWRQWRUHVXPHDXWRPDWLFRSHUDWLRQ3OHDVHUHIHUWRH[SODQDWLRQEHORZ
3. The mode will change to AUTO Mode after power failure.
Auto Mode [ ]
Press button to in initiate automatic mode. The sensor starts working and all settings remain as before the light was switched ON/OFF.
RESET [ ]
Press button , all settings go back to the value of DIP switch settings.
Test 2s function [ ]
3UHVVEXWWRQWKHVHQVRUJRHVLQWRWHVWPRGHKROGWLPHV1%WKHVWDQGE\SHULRGDQGGD\OLJKWVHQVRUVHWWLQJVDUHGLVDEOHGLQWHVWPRGH
2.Press button to exit from this mode, and the sensor settings are changed accordingly.
Ambient daylight threshold [ ]
Press button , the latest surrounding lux value overwrites previous lux value learned, and is set as the daylight threshold. This feature enables the fixture
to function well in any environment.
1
2
3
2 3 4
button
1
button
2
button
3
8
3
10
4 11
button
8
button
10
Power output [ ]
Press button , the output shifts between 80% and 100%, for energy saving purposes.
5
button
5
Dim +/- [ ]
Press button to adjust the light brightness between 10%~100% during hold-time.“+” increases the light level, “-” will decrease the light level.
9
button
9
Lux disable [ ]
Press button , the built-in daylight sensor is disabled, the light will always operate upon detection regardless of ambient light level.
14
button
14
5
9
4
11
12
Stand-by dimming level
Detection range
ON/
OFF
Auto Mode
Reset
Power
80%
Test
2s
10%
20%
30s
1min
100%
30min
10min
5min
0s
10s
1min
30%
SC1
SC2
SC3
Scene mode
10min
50%
10%
30min
Hold-time
Stand-by period
5min
Lux
Disable
2Lux
10Lux
50Lux
Daylight Sensor
SC4
Power
100%
+
-
Dim
M/A
3
1
2
7
8
6
10
13
14
15
HRC-05
Note: the buzzer beeps one time when RC
receives signal successfully
Detection range [ ]
Press buttons in zone to set detection range at 100% / 50% / 10%.
Hold time [ ]
Press buttons in zone to set hold time at 30s / 1min / 5min / 10min / 30min.
Stand-by period [ ]
3UHVVEXWWRQVLQ]RQHWRVHWWKHVWDQGE\SHULRGDWVVPLQPLQPLQ
1RWH³V´PHDQVRQRIIFRQWURO³
” means bi-leve of dimming control, the light will never switch off.
LHWKHOLJKWUHPDLQVDWWKHVWDQGE\GLPPLQJOHYHOXQWLOPRWLRQLVGHWHFWHG
Stand-by dimming level [ ]
Press buttons in zone to set the stand-by dimming level at 10% / 20% / 30% .
Daylight sensor [ ]
Press buttons in zone to set daylight sensor at 2lux / 10lux / 50lux.
6
Press button ,the sensor goes to manual override or semi-auto function.
15
11
13
12
7
Manual override/ semi-auto [ ]
Note: The buzzer beeps twice if it is in manual override mode, and beeps once if shifts to semi-auto mode.
button
15
zone
6
zone
11
zone
12
zone
7
zone
13
Scene mode options [ ]
Note: the end-user can fine tune the settings by pressing buttons of detection range / hold time / stand-by period / stand-by dimming level
/daylight sensor , the last setting will over-write that feature of the pre-set scene.
6
11
13
12
7
zone
4
There are 4 scene modes built into the remote control for different applications:
Scene options Detection range Hold time Stand-by period Stand-by dimming leve
Daylight sensor
SC1 100% 1min 10min 10%
2Lux
SC2 100% 5min 10min 10%
2Lux
SC3 100% 10min 30min 10%
10Lux
SC4 100% 10min + 10%
50Lux
8