TM-800 UHF SERVICE MANUAL
147
Receiver
Measurement
Adjustment
Item
Condition
Test Instrument
Terminal
Part
Method
Specification
/Remarks
15. RF
bandpass
filter
Enter adjustment
item “10”, each Ch
corresponds to a
specific RX Freq
Scanner ANT
.
TP1
Adjust
software
settings
Adjust the gain to
the Max. value, the
corresponding freq
is on the rightmost
to bandpass
waveform. Press
[PF6] to save.
16. max
SINAD
CH: RX Center,
turn to CH1(C);
corresponds to a
specific RX Freq
Radio Communication
Test Set
SSG output: -47dBm
MOD:1KHz
DEV:±3KHz(W)
±1.5KHz(N)
FILTER: 0.3-3.0KHz
ANT
SP Jack
L135
Adjust the
L135,make SINAD
is max
The max volume :
4.6V or higher
1.CH: RX Center,
turn to CH1(C) in
manual adjust mode
2. CH: RX LO, turn to
CH2(L) in manual
adjust mode
17.
Sensitivity
3.CH:RX HI, turn to
CH3(H) in manual
adjust mode
Radio Communication
Test Set
SSG output:
-118dBm
MOD:1KHz
DEV:±3KHz(W)
±1.5KHz(N)
FILTER: 0.3-3.0KHz
ANT
SP Jack
W/N switch
(turn on power
while holding
down [PF6] to
enter Channel
Set Mode)
[UP]/ [DOWN] to
change channel
Check
SINAD:
12dB or higher