background image

S570/3 

 

 

 

 

 

 

 

PRODUCT DESCRIPTION  

 

Range of 1” electronic turbine meters designed to be fitted in line with the 
delivery pipework or by the nozzle. Not suitable for resale. 

 

SPECIFICATION 

 

FM.DN1

 - Turbine flowmeter, nylon body, 1" BSP ports for AdBlue®. 

FM.DA1

 - Turbine flowmeter, aluminium body, 1" BSP ports for diesel. 

 
Flow rate:    

10-100L 

Accuracy:    

+/- 1% when calibrated. 

Ports:    

 

1” F BSPP 

Register:    

5 digits 

Totaliser:    

7 digits 

Max pressure:   145PSI (10 BAR) 

 

INSTALLATION INSTRUCTIONS  

 

This meter is

 

designed to be fitted in line with the delivery pipework or by 

the  nozzle.  Ensure  all  threaded  joints  are  sealed  with  a  suitable  thread 
sealant or PTFE tape.  
Please see manufacturer’s instructions for additional technical information, 
exploded diagrams, troubleshooting guide etc. 

 

 

 

 

 

 

ENVIRONMENTAL INFORMATION 

European  Directives  2002/96/EC  and  2003/108/EC  require  that  the 
equipment  bearing  this  symbol  on  the  product  and/or  its  packaging 
must  not  be  disposed  of  with  unsorted  municipal  waste.    The  symbol 
indicates that this product must be disposed of separately from regular 
household  waste  streams.    It  is  your  responsibility  to  dispose  of  this 
and  other  electric  and  electronic  equipment  via  designated  collection 
facilities appointed by the government or local authorities

 

Summary of Contents for FuelWorks FM.DN1

Page 1: ...nly FM DN1 FM DA1 Please read carefully before commencing installation Registered Office HYTEK GB LIMITED Delta House Green Street Elsenham Bishop s Stortford CM22 6DS UK Registered in England No 1915382 Tel 44 0 1279 815 600 Fax 44 0 1279 812 978 email info hytekgb com Web www hytekgb com ...

Page 2: ...work or by the nozzle Ensure all threaded joints are sealed with a suitable thread sealant or PTFE tape Please see manufacturer s instructions for additional technical information exploded diagrams troubleshooting guide etc ENVIRONMENTAL INFORMATION European Directives 2002 96 EC and 2003 108 EC require that the equipment bearing this symbol on the product and or its packaging must not be disposed...

Page 3: ...nput screen The first digit will now flash 5 We now need to input 020 00L into the display Press the RESET button to select the correct digit Once the correct digit is displayed press the MENU button to scroll to the next digit Continue until 020 00L is displayed 6 Now press and hold the MENU button to exit the calibration menu 7 Carry out a test measure to ensure that the new calibration setting ...

Page 4: ...19 EU Waste Electrical Electronic Equipment Regulations 2011 65 EU Restriction of Hazardous Substances Directive RoHS2 Authorized By Clive Wellings Technical Manager Hytek Declaration number EC084 On behalf of the above named company I declare under our sole responsibility that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technic...

Reviews: