S855/2
ERRORS
If an error occurs
ERROR
, followed by a brief description is shown on the
lower display. The errors are classified as follows:
FLOW TOO FAST
The pulser has run too fast (in excess of 300 pulses
per second)
UNAUTH FLOW
The meter has turned without the nozzle being
removed
CALIBRATE FAIL
A time delay of 2 minutes or more has occurred
during the 20 litre calibration.
PULSER SIGNAL
One of the pulse transmitter’s pulse trains has been
interrupted.
PULSE REVERSE
The meter has run backwards during a delivery
PULSER POWER
The pulser has been disconnected
The error condition is maintained until the nozzle is returned to its holster,
for at least 2 seconds, and then removed again to restart the fuelling
sequence.
TIMEOUT
If, during a delivery, no fuel is dispensed for 2 minutes the display will
show
TIMEOUT
alternating with
REPLACE NOZZLE
and the pump will
stop running until the nozzle is returned to its holster, for at least 2
seconds, and then removed again to restart the fuelling sequence.