Hysolis PPS1000iL Owner'S Manual Download Page 30

- 29 - 

 

 NOTE  

1. This APP can be only connected to power stations with Gen-mate 
(monitor) installed inside. 
2. For some models, the monitor Wi-Fi from power station is 
available only after the Main Switch 1 is turned on. 
 

 

 

11.2 Click on the gen-mate icon on the phone screen to enter the gen-
mate APP. Click "Management" item at the bottom of the APP screen, 
and then enter the "Management" page. 

1

Summary of Contents for PPS1000iL

Page 1: ...OWNER S MANUAL PPSiL Series Smart Mobile PPS1000iL PPS1500iL PPS2000iL POWER VER1 0 20201022...

Page 2: ...15 5 2 INSTALL THE BATTERY 17 5 2 1 BIND THE BATTERY 17 5 2 2 REINSTALL THE BATTERY INTO THE MOBILE POWER 18 5 2 3 CONNECT THE BATTERY 19 6 TRANSPORTATION AND STORAGE 20 7 PROTECTION 21 7 1 INPUT PRO...

Page 3: ...building electrical system unless an isolation switch has been installed by a qualified electrician Place the generator in a place where pedestrians children and pets are not likely to touch Do not l...

Page 4: ...receptacles 3 Maintenance Cover Remove the cover to install or replace battery in the mobile power 4 Carrying Handle Lift the generator by this handle 5 Draw Bar Handle Pull the handle to wheel this...

Page 5: ...or OFF DC output of the mobile power and AC Switch is available only after the main switch is turned on 4 Cigarette Lighter Receptacle 12V DC output receptacle for cigarette lighter plug 5 USB Recepta...

Page 6: ...y backlight or value display for battery voltage by pressing the button 10 Display button S You can activate the display backlight by pressing the button and the factory or authorized dealer can use t...

Page 7: ...ing Input Charge the mobile power from solar panels 2 DC Charging Input Charge the mobile power from car or any 12V 24V source 3 AC Charging Input Charge the mobile power from wall outlet or other AC...

Page 8: ...OTE When the mobile power is charging the battery segments in the LCD screen will blink The mobile power is fully charged when all battery segments in the LCD screen stop blinking and remain solid You...

Page 9: ...8 You can charge the mobile power from solar panels as follows 1 Remove the cover 1 from PV charging port 2 2 Connect PV charging port 2 to MC4 port 5 of solar panels 4 by PV 4 3 3 5 4 3 5...

Page 10: ...g box 2 2 AC CHARGING INPUT You can charge the mobile power from wall outlet or other AC source as follows Connect AC charging port 1 to any wall receptacle by the AC charging cable 2 which can be fou...

Page 11: ...follows Connect DC charging port 1 to cigarette lighter receptacle of 12V or 24V car by DC charging cable 2 which can be found in the packing box NOTE The car engine must run when charging the power...

Page 12: ...re the receptacle load current is within receptacle rated current If the DC output is overloaded in excess of rated current or if there is a short circuit in a connected appliance the icon and icon in...

Page 13: ...mes Do not operate with wet hand Do not operate by children without supervision Do not expose the mobile power to rain moisture or snow NOTE Be sure all electric devices including the lines and plug c...

Page 14: ...y charged when all battery segments stop blinking and remain solid If the remaining capacity of the battery it too low the battery segments become blank and will blink as a prompt of recharging INPUT...

Page 15: ...e battery while charging Shows remaining operation hours of the battery while discharging POWER icon will show when the Gen mate unit optional equipment inside the mobile power is operating normally W...

Page 16: ...until the warning icons clear 5 REPLACE THE BATTERY Read the instructions before you begin and make sure you have the tools and skills required Shut off the mobile power before starting to replace th...

Page 17: ...16 Loosen Screws 1 4 3 5 4 6 4 2 Loosen Loosen 2...

Page 18: ...tor 2 3 Loosen the screws 5 6 with a box spanner 3 to remove the battery baffle plate 4 The spanner 3 can be found in the packing box 4 Hold the bandage 7 that is bound to the battery and then take ou...

Page 19: ...igure above 3 Bind the bandage 1 around the battery 2 4 Make sure the bandage 1 through the metal buckle 3 and pressed tightly by the metal buckle 3 as shown in the figure above 5 The metal buckle 3 s...

Page 20: ...te 2 into the bottom hole on the battery support and then tighten the screw 3 4 with a box spanner 5 which can be found in the packing box 3 Make sure the metal buckle 6 has enough distance from the b...

Page 21: ...the five screws to reinstall the maintenance cover 1 4 Make sure the battery connector 3 is connected securely together 5 Put the battery connector 3 into the right place in the mobile power through...

Page 22: ...down and the all battery segments in the LCD screen will stop blinking and remain solid Battery Low Voltage Protection When the battery voltage is too lower the DC and AC output will automatically shu...

Page 23: ...ut down The buzzer alarm will sound 5 times uninterruptedly and the warning light flashes 5 times at the same time Turn off the electrical appliance connected to the mobile power and put the mobile po...

Page 24: ...correct condition of any extension cords and all items being powered then push the main switch to reset module Is the DC output overloaded The fault indicator on the screen panel or APP flashes Reduc...

Page 25: ...h to the ON position YES NO NO Is the AC switch OFF Push the AC switch to the ON position YES NO Does the over temperature indicator on the screen panel or APP go on Turn off the electrical appliance...

Page 26: ...Reduce loads and push the AC switch to reset module YES Is the AC output overloaded The warning light on the panel flashes Check and correct condition of any extension cords and all items being powere...

Page 27: ...2048Wh 80Ah 25 6V Battery Cycle Life 2000 cycles OUTPUT AC Output Output Waveform Pure Sine Wave THD 3 Rated Voltage 120V Rated Frequency 60Hz DC Output Cigarette Lighter 12V 10A 6mm Port 12V 6A USB...

Page 28: ...and install For iOS system download Gen mate APP from App Store and install as instructed For Android system download Gen mate APP from Google Play and install as instructed 10 2 Click Free register...

Page 29: ...nd password 11 Add Power Station Into The APP 11 1 Open the WLAN on the phone to choose Wi Fi sent from power station s monitor and connect The Wi Fi signals are named with the starting of power stati...

Page 30: ...ed inside 2 For some models the monitor Wi Fi from power station is available only after the Main Switch 1 is turned on 11 2 Click on the gen mate icon on the phone screen to enter the gen mate APP Cl...

Page 31: ...30 11 3 Click on Add device choose the WIFI signal that matched with your power station model in Devices detected page click on the Quick Add on the right side of the signal...

Page 32: ...ll need to turn off the WLAN first but keep the page on Then open the mobile network to make sure mobile phone can connect to the mobile network and then click OK in the New devices screen You can see...

Page 33: ...power station is added in management it will be kept in it unless you delete it by yourself 12 Connecting And Monitoring Power Station 12 1 Turn on the WLAN on the phone and connect the Wi Fi from po...

Page 34: ...toring page You can monitor the following items Battery Remaining Power Power Current Voltage Frequency Total Power Output DC Power DC Total Power Output Charging Power PV Voltage PV Total Power Input...

Page 35: ...34...

Page 36: ...ery error DC output is overloaded or short circuited Charging over current Battery under voltage or Battery over voltage Right Warning Indicator at the bottom of Monitoring page will flicker when the...

Page 37: ...he APP Then you can turn off the WLAN and turn on the mobile network When you enter the APP again the power station picture will be successfully downloaded 13 2 When you connect to the power station a...

Page 38: ...connected to the Wi Fi from power station while you monitor the power station During the whole process of using only when you use it for the first time you need to use mobile network shortly when you...

Page 39: ...ck on trouble shooting and do trouble shooting with the step by step guide 15 Turn On AC Output Of Power Station By The APP To make sure your smartphone is connected to the Wi Fi from power station yo...

Page 40: ...e If it is placed at the open zone the max monitoring distance can exceed 100 meters 16 Turn Off AC Output Of Power Station By The APP To make sure your smartphone is connected to the Wi Fi from power...

Page 41: ...cal loads connected to the power station before shutting down The environment can influence the max control distance between generator and APP in smartphone If it is placed at the open zone the max co...

Page 42: ...More power More smart EASY POWER WITH YOU www hysolis net...

Reviews: