Section 6
— Internal Solenoid Lock Instructions
Internal Solenoid Lock Description:
HySecurity offers an optional internal solenoid deadbolt lock that employs a ¾ inch stainless steel lock pin that fits into a
notch cut into the drive rail. The lock solenoid is voltage specific for 120V, 208V, 230V, or 480V, therefore be certain that
the operator voltage matches the solenoid voltage requirements. An internal indicator switch is also provided which may
be required in some installations in order to verify whether the deadbolt is in the locked or unlocked position.
Activation of a Solenoid Deadbolt Lock:
A solenoid lock must be activated prior to any gate motion or the gate will bind the lock mechanism. HySecurity’s internal
lock must also remain engaged until the soft stop time cycle is complete at the end of travel. To provide the solenoid lock
logic requirement, one of the three user relays (typically user relay 2) must be set to function #6 and wired to supply
power to the lock solenoid. The same relay function can easily be used to drive an external solenoid lock device as well.
Adjustment of the Factory Solenoid Lock:
Operators equipped with our factory solenoid lock require a notch to be cut into the outer vertical face of the drive rail. The
notch location is determined in the field after the gate operator is functioning properly. Run the gate to its full closed
position and note the location where the deadbolt pin strikes the drive rail. Mark for a 3-inch wide slot in the rail with the
lock pin in the center. Make two cuts with a hacksaw and break out the notched section. Operate the gate a few times to
verify that the deadbolt always enters the notched area.
The lock enclosure itself may need to be adjusted so that the lock pin strikes in the center of the vertical edge of the drive
rail. The face of the lock enclosure is slotted to accommodate this adjustment. With a ½ inch open end wrench, loosen the
two bolts retaining the lock enclosure and move the enclosure up or down to achieve the correct adjustment.
Electrical:
When the factory pre-installs the internal solenoid deadbolt lock, a terminal strip and an auxiliary contactor are added.
The two (2) high voltage wires to the solenoid attach directly to the auxiliary contactor as shown. Indicator lights or
interlocks can be connected to the contacts brought back to the terminal strip.
Summary of Contents for SlideDriver 50VF2
Page 2: ......
Page 28: ...14 2012 Installation and Reference Manual D0125 Rev H Section 2 Technical Drawings...
Page 29: ...15 2012 Installation and Reference Manual D0125 Rev H Section 2 Technical Drawings...
Page 36: ...22 2012 Installation and Reference Manual D0125 Rev H Section 3 Wiring Control Inputs...
Page 63: ...49 2012 Installation and Reference Manual D0125 Rev H Section 6 Internal Solenoid Lock Drawing...
Page 64: ...50 2012 Installation and Reference Manual D0125 Rev H Section 6 Internal Solenoid Lock Drawing...
Page 81: ...68 2012 Installation and Reference Manual D0125 Rev H...