HyQuest Solutions Pty Ltd
WS200/WS300/WS500
Page
7 of 28
©
Copyright
During Operation
Rotate the handle in a counter-clockwise direction until the “underside” of the gauging weight
touches the surface of the water.
At this instance, you need to reset the mechanical counter on the winch. Please note do not
reset the counter while rotating as it may cause the number reels to momentarily jam. If this
happens, stop rotating the handle and then press the reset button again.
•
Lower the current meter and weight to 0.2m, 0.6m or 0.8m of the water level and measure
the velocity
MAINTENANCE
The
only
maintenance
required
is
to
lightly
oil
or
grease
the
Layer
winding
screw
periodically.
This
usually
is
required
if
the
lead
screw
appears
to
be
“dry”
or
if
the
sheave
is
emitting
“squealing”
noise
when
rotating.
Mechanical Counter
Layer Winding Screw
ISSUE 3:11/6/19