HyQuest Solutions
ML-IoT/C and /N Operation Manual © Copyright
Page -
36
Issue 1.2 28 Jun, 2021
16
Communications Link
LinkType=
DIS, WIFI, LTE
17
Application Type
ApplType=
DIS, FTP, HTTP, MQTT
18
File Format
FileFmt=
CSV, JSON, DAS
19
WiFi connection
WiFiSSID=
*
32 char max
20
WiFi Password
WiFiPwd=
*
20 char max
21
LTE Access Point Name
LTEAPN=
*
20 char max
22
LTE Username
LTEUser=
*
30 char max
23
LTE Password
LTEPwd=
*
30 char max
24
LTE Band
LTEBand=
0,1,2,3,4,5,8,12,13,14,
17,18,19,20,25,26,28,66
0=>Scan All
25
Application Type
ApplType=
DIS, FTP, HTTP, MQTT
26
FTP/HTTP Host Address
MQTT Broker Address
ApplHost=
*
64 char max
27
FTP/HTTP/MQTT Port
Number
ApplPort=
1 to 65535
1 to 5 digits
28
FTP/HTTP/MQTT SSL
ApplSsl=
EN, DIS
29
FTP/HTTP/MQTT
Username
ApplUser=
*
70 char max
30
FTP/HTTP/MQTT
Password
ApplPwd=
*
150 char max
31
FTP Path
HTTP URI
MQTT Topic
ApplPath=
*
48 char max
32
MQTT Client-ID
ApplID=
*
12 char max
33
Azure Key
AzureKey=
No limit
34
Azure Expiry (epoch)
AzureExpiry=
No limit
35
Email Schedule
EmailSched=
off, 1h, 6h, 12h, 24h
36
Email Disable / Port
EmailPort=
25 / 465 / 587
Port Number
37
Email Host Address
EmailHost=
*
30 char max
38
Email Username
EmailUser=
*
50 char max
39
Email Password
EmailPwd=
*
30 char max
40
Email Sent to
EmailTo=
*
50 char max
41
Email Cc to
EmailCc=
*
50 char max
42
SDI-12 #1 Configuration
SDI1=
Addr, cmd, var#, dec
places, mult, offset
Eg.
0,M,1,3,1.0,0.0
43
SDI-12 #2 Configuration
SDI2=
“
44
SDI-12 #3 Configuration
SDI3=
“
45
SDI-12 #4 Configuration
SDI4=
“
46
SDI-12 #5 Configuration
SDI5=
“
47
SDI-12 #6 Configuration
SDI6=
“
48
SDI-12 Warm Up Time
SDIWUT=
1 to 99
secs
Blank Parameter
“”
Marked with a *