Please note that the customs invoice / dispatch documents should also clearly state: “Goods being re-

turned to manufacturer for repair 

 

No Commercial value”. It is mandatory to have any returned goods 

accompanied by a commercial invoice on headed paper. HyQuest Solutions reserves the right to charge 
the customer for time spent rectifying incorrect customs documents. 
 
Note: Please ensure that your goods are packed carefully and securely. Damage that occurs during 
transit is not covered by our warranty and may be chargeable. 

 

Technical Data

 

Technical 

Specifications

 

HyQual 200

 

HyQual 300

 

HyQual 300T

 

Diameter

 

50 mm 

(1.95”)

 

75 mm 

(2.95”)

 

75 mm 

(2.95”)

 

Length

 

47.8 cm 

(18.8”)

 

47.8 cm 

(18.8”)

 

47.8 cm 

(18.8”)

 

Mass

 

0.82 kg (1.8 lbs.)

 

1.63 kg (3.6 lbs.)

 

1.63 kg (3.6 lbs.)

 

Standard

 

Temperature sensor, dissolved oxygen sensor, specific conductivity sensor, pH sensor 

and ORP sensor, calculated total dissolved solids, calculated salinity, interface RS-232, 

weighted sensor guard, internal memory (months of datalogging), maintenance kit, car-

rying case, non-vented underwater cable (5, 10, 20, 30, 40 and 50 m)

 

 

 

Turbidity sensor, wiper

 

Options

 

 

Depth (level) sensor, barometric pressure, vented capacity, data 
cable for display devices (not for 

eld use), calibration solutions, 

copper anti-fouling kit, USB adapter (connect DB9 to USB), inte-
grated SDI-12 and MODBUS output, SDI-12 adapter cable, MODBUS 
adapter cable and Android display

 

  

Material

 

                   Resistant materials like stainless steel 303 and 316, 

polyacetal (Delrin), PVC, Teflon, ABS, titanium, Viton, 
neoprene, silicone, glass

 

     

Power Supply and Consumption

 

-Supply: underwater cable (incl.), or 

Bluetooth

® wireless technology   

                                                                                    battery pack (opt.), or  External

 

battery pack (opt.) 

 

 

-Consumption: depends on the number of sensors, logging interval and site          

                                                                                    conditions.              
                                                                                    Battery dimensioned to ensure long autonomy. 

-

 

Rechargeable External Lithium Battery choices (optional): Spot measurement:   

  Bluetooth  battery pack that operates at the surface. Continuous logging: Bat- 
  tery that operates underwater, with the same diameter as HyQual 300/300 T  
  but it fits HyQual 200.   

Output Options (Interfaces)

 

Standard: RS-232. Optional: 

Bluetooth

® wireless technology, SDI-12, MODBUS) 

Certifications 

 

CE, RoHS (WEEE pending) 

 

 

Obligations of the Operator and Disposal

 

When disposing of the units and their accessories, the applicable local regulations regarding environ-
ment, disposal and occupational safety must be observed. 
Before dismantling: 

 

Electrical Devices: 

o

 

Switch off the units. 

o

 

Disconnect electrical appliances from the power supply, regardless of whether the appli-
ances are connected to the mains or to another power source. 

 

Mechanical devices: 

o

 

Fix all loose components. Prevent the device from moving independently or uninten-
tionally. 

Summary of Contents for HyQual

Page 1: ...HyQual Water Quality Multi Probe HyQuest Solutions KISTERS Group 2022 05 03...

Page 2: ...ction 10 6 2 2 Unattended Logging 10 6 2 3 Telemetry Relay 11 6 2 4 On Line Monitoring 12 7 1 When to proceed to maintenance 12 7 2 Maintenance 1 Keep your device clean 12 7 3 Maintenance 1 Calibratio...

Page 3: ...ilidad de tales da os Cualquier error encontrado en cualquier producto de HyQuest Solutions debe ser comuni cado a HyQuest Solutions donde se har todo lo posible para resolver r pidamente el pro blema...

Page 4: ...industrial specification that defines the electrical interface and physical layer for point to point communication of electrical devices The RS 485 stand ard allows for long cabling distances in elec...

Page 5: ...s battery operates only at the surface and its job is to power the multiprobe while you re pairing the instrument with a data display via Bluetooth wireless technology A USB port on a PC is another wa...

Page 6: ...send the probe back to us at your own expense Additional sensors Barometric pressure is calculated with the use of the depth sensor therefore you will need to add an optional depth sensor to any of yo...

Page 7: ...ufacturer s named repair center You can find information on how to re turn items for repair in the relevant section of the HyQuest Solutions website Disposal instructions After taking any HyQuest Solu...

Page 8: ...ufficient water flow that can be easily ac cessed for maintenance and protected from external elements such as animals and items such as stones or sticks that may damage the probe 4 1 Protection for u...

Page 9: ...n to toggle between Logging ON and Logging OFF The Setup function for Logging lets you name your Logging file and set the logging interval time be tween logged lines of data Figure 1 Switch Logging ON...

Page 10: ...The Display can be a laptop or almost any tablet or smart phone You can record measurements using the HyQual probe s Snapshot or Automatic Snapshot features You might snapshot a series of measurements...

Page 11: ...rchase this battery after as it is not integrated to the probe Please note that this battery ads several inches to the length of the probe and that it can also be used with the HyQual 200 only that it...

Page 12: ...ed in the control loop or decision making process Maintenance 7 1 When to proceed to maintenance Judgment gained from observing your field conditions and data requirements provides information about w...

Page 13: ...tuation for which the correct parameter value is known Here s the general procedure 1 Clean the sensor and perform any necessary sensor specific maintenance 2 Select a calibration standard whose value...

Page 14: ...c But you can elect to accept any SRF 7 3 3 Choosing Calibration Standards For best results choose a calibration standard whose value is close to what you expect to see in the field For example calibr...

Page 15: ...ate of the calibration the parameter calibrated the reading before the calibration was accepted the read ing after the calibration was accepted the raw sensor reading the SRF and a few other details I...

Page 16: ...follow the calibration instructions on the screen The manufacturers of optical DO sensors usually recommend that you not calibrate the zero DO point because the zero DO point drift is very low However...

Page 17: ...don t report because it has little meaning in natural waters You can t calibrate TDS or salinity directly because they are calculated from Conductivity You can however calibrate TDS with a TDS standar...

Page 18: ...ous circle at the end of the sleeve This not only purges bubbles from the electrolyte but also cleans nasty stuff out of the junction Figure 4 Filling in fresh pH reference electrolyte 7 3 10 ORP ORP...

Page 19: ...s a small hole in the back of the transducer There is a tube inside the cable i e a Vented Cable to connect the Stage sensor to the atmosphere so that changes in barometric pressure will not affect t...

Page 20: ...e small set screw on the wiper arm 2 Remove the wiper pad from the wiper arm and replace the pad 3 Place a new wiper arm on the motor shaft so that the set screw faces the flat spot on the motor shaft...

Page 21: ...bor charge 1 2 days down time Repair HyQuest Solutions precision instruments and data loggers are produced in quality controlled processes All HyQuest Solutions production and assembly sites in Austra...

Page 22: ...lay devices not for eld use calibration solutions copper anti fouling kit USB adapter connect DB9 to USB inte grated SDI 12 and MODBUS output SDI 12 adapter cable MODBUS adapter cable and Android disp...

Page 23: ...ion battery must be dis posed of according to legal provisions EU WEEE Directive As players in the environmental market KISTERS AG and HyQuest Solutions are committed to supporting efforts to avoid a...

Reviews: