Pump Performance
350 RPM
400 RPM
450 RPM
500 RPM
550 RPM
PSI GPM
HP
GPM
HP
GPM
HP
GPM
HP
GPM
HP
0 27.9
0.61
32.1
0.80
35.1
1.03
38.9
1.33
41.9
1.68
72 26.4
1.51
30.0
1.73
33.6
2.01
37.1
2.18
40.9
2.50
145 25.4
2.48
28.7
2.91
32.6
3.28
35.7
3.74
38.9
4.13
217 24.3
3.45
27.7
4.06
31.0
4.58
34.4
5.13
37.6
5.73
290 23.6
4.50
26.9
5.18
30.2
5.86
33.7
6.45
36.8
7.26
Series
D160
U.S. Units
350 RPM
400 RPM
450 RPM
500 RPM
550 RPM
BAR LPM
HP
LPM
HP
LPM
HP
LPM
HP
LPM
HP
0 105.3 0.61 121.0 0.80 132.3 1.03
146.6 1.33 158.1 1.68
5 99.7
1.51 113.1 1.73 127.0 2.01
139.9 2.18 154.2 2.50
10 95.7
2.48 108.5 2.91 122.9 3.28
134.8 3.74 146.8 4.13
15 91.8
3.45 104.5 4.06 117.0 4.58
129.8 5.13 141.9 5.73
20 89.1
4.50 101.6 5.18 114.1 5.86
127.0 6.45 138.9 7.26
Series
D160
Metric Units
350 RPM
400 RPM
450 RPM
500 RPM
550 RPM
PSI GPM
HP
GPM
HP
GPM
HP
GPM
HP
GPM
HP
0 42.7
0.71
48.4
0.90
54.3
1.22
59.8
1.60
65.7
2.01
72 41.4
2.33
47.2
2.73
52.7
3.10
58.1
3.45
63.3
3.88
145 40.1
4.09
45.9
4.73
52.1
5.27
56.6
6.02
61.3
6.45
217 39.3
5.70
45.1
6.58
50.7
7.45
55.5
8.32
60.2
9.22
290 38.8
7.52
44.5
8.45
50.1
9.66
54.8 10.89 59.2 11.54
Series
D250
U.S. Units
350 RPM
400 RPM
450 RPM
500 RPM
550 RPM
BAR LPM
HP
LPM
HP
LPM
HP
LPM
HP
LPM
HP
0 161.2 0.71 182.5 0.90 204.8 1.22
225.7 1.60 248.1 2.01
5 156.1 2.33 178.2 2.73 198.9 3.10
219.4 3.45 239.0 3.88
10 151.4 4.09 173.1 4.73 196.4 5.27
213.8 6.02 231.2 6.45
15 148.5 5.70 170.0 6.58 191.5 7.45
209.5 8.32 227.1 9.22
20 146.4 7.52 167.9 8.45 189.0 9.66
206.9 10.89 223.4 11.54
Series
D250
Metric Units
NOTE
:
“HP” is electrical
horsepower.
Consult your gas
engine supplier for
engine horsepower
required.
L-1381 (Rev. B)
Oil crankcase capacities are approximate. Fill
oil to proper level in sight glass. Always make
sure all the air is purged out of crankcase
prior to operating.
19