- 4 -

Introduction

Description

Hypro Piston

 

pumps are designed for creating and boosting pressure in fluid circuits. The pump operates by taking in fluid 

from the inlet port after which it is slung by the piston and expelled through the outlet port. Construction features come in 

a variety of materials in order to be resistant to a range of chemicals.  Standard models of Piston pumps shaft rotation is 

bi-rotational. 

Intended Uses

Hypro Piston pumps are intended for creating or boosting dynamic pressure in approved fluids. Hypro Piston pumps 

should never be used to pump liquids above 140°F (60°C), or below 34°F (1°C). Any uses outside of those specified in 

this manual are considered misuses and are prohibited. Contact Hypro technical service with any questions regarding 

specific acceptable uses.

Purpose of Manual

This manual provides instructions and requirements that must be met when installing, using and maintaining the 

product(s) identified on the cover.

If the product is sold, the seller must pass this manual onto the new owner.

The following special attention notices are used to notify and advise the user of this product of procedures that may be 

dangerous to the user or result in damage to the product.

ATTENTION

Attention is used to notify of installation, operation, or maintenance information that is important but not safety related.

This symbol is used to denote the presence of an electrical hazard that will result in personal injury, death or property 

damage.

This symbol is used to denote the presence of a hazard that will result in personal injury, death or property damage.

California Proposition 65 Warning 

-- This product and related accessories contain chemicals known to the

State of California to cause cancer, birth defects or other reproductive harm.

Misuses

Hypro Piston pumps are designed to operate effectively within the specified speed, pressure and environmental ranges. 

Going outside of these ranges will void the warranty and could cause damage to property or serious injury or death.

•  DO NOT 

run the pump faster than the maximum specified speed.

•  DO NOT

 run the pump higher than the maximum specified pressure. 

•  DO NOT

 run pumps when the liquid has exceeded the maximum or minimum temperature limit (see Intended Uses).

•  DO NOT

 pump non-approved liquids.

•  DO NOT

 pump water or other liquids for human consumption.

•  DO NOT

 operate any pump under the influence of drugs or alcohol.

•  DO NOT

 run the pump dry.

Summary of Contents for 5315C Series

Page 1: ...esentative QNET BV Hommerterweg 286 6436 AM Amstenrade The Netherlands KvK Zuid Limburg 14091511 EC REP Hypro Small Twin Piston and Plunger Pumps Form L 1574 Rev B Original Instruction Manual KEEP FOR...

Page 2: ...ssemblyandInstallation 11 Assembly 11 Installation 11 Plumbing Diagram 12 Belt Pulley Drive Inst 13 Direct Drive Hollow Shaft Inst 14 Commissioning Start Up Operation Shutdown 15 Information 15 Start...

Page 3: ...are a www hypropumps com Italian Hypro www hypropumps com Russian NO intente instalar su bomba antes de leer el manual Copias originales del manual para Hypro se provee de bombas en ingles Para encont...

Page 4: ...er of this product of procedures that may be dangerous to the user or result in damage to the product ATTENTION Attention is used to notify of installation operation or maintenance information that is...

Page 5: ...C F E B D C F E B D C A E G F H I B D E G F H I 5315C HX 5320C HX 5325C CH 5315C X 5320C X 5325C X Pump Dimensions Dim Inch mm All Models A 5 20 132 08 B 5 23 132 84 C 2 56 65 02 D 2 60 66 04 5315C HX...

Page 6: ...mp Dimensions Dim Inch mm All Models A 5 76 146 30 B 5 13 130 30 C 2 56 65 02 D 2 88 73 15 5321C H E 5 26 133 60 5322C H E 5 11 139 74 5324C H E 4 93 125 22 5321C H F 1 53 38 86 5322C H F 1 45 36 83 5...

Page 7: ...sure PSI BAR Max RPM Ports Dry Weight Mounting bolts 5315C X PTO 5 8 OD solid shaft 1 5 5 7 500 34 5 1800 1 2 NPT Inlet Outlet 11 lbs 5kg 3 8 or M10 5320C X 2 2 8 3 5325C X 2 5 9 5 5330C X 3 11 4 5315...

Page 8: ...8 0 41 1 97 0 55 2 38 0 67 1 87 0 80 400 0 96 0 33 1 47 0 50 1 96 0 67 2 37 0 83 2 85 1 00 500 0 94 0 39 1 47 0 60 1 96 0 81 2 36 0 97 2 83 1 19 600 0 93 0 45 1 46 0 69 1 95 0 93 2 35 1 13 2 81 1 38 7...

Page 9: ...T 900 RPM AT 1200 RPM AT 1450 RPM AT 1725 RPM 6 9 4 2 0 2 5 7 0 30 6 8 0 40 8 30 0 40 20 7 4 2 0 4 5 7 0 50 6 8 0 60 7 90 0 70 34 5 4 2 0 5 5 7 0 60 6 8 0 70 7 90 0 80 48 3 4 2 0 6 5 7 0 80 6 8 0 90 7...

Page 10: ...ing at the attached packing slips to establish what lifting equipment should be used Before installing the pump determine if all the components are present and undamaged If the pump is missing compone...

Page 11: ...rotect the hands from any sharp surfaces on the pump or chemicals Pumping systems must be installed in accordance with Hypro installation instructions Failure to do so will void your warranty and coul...

Page 12: ...ne from its electricity supply should be provided Standard Mounting In order to prevent injury or damage to property all Hypro pumps should be properly mounted to a solid base where there is no danger...

Page 13: ...Typically a pulley diameter on the motor is 3 4 inches The pump pulley diameter can be determined from the formula above 1725 RPM Pump Pulley Dia 950 RPM 3 4 Solving this equation for the Pump Pulley...

Page 14: ...d Installation section of this manual Direct Drive Hollow Shaft Installation Hollow shaft models mount directly on the motor or engine shaft After mounting the pump always turn it by hand to make sure...

Page 15: ...ing Never leave electrical wires or plumbing components where they can be a tripping hazard or become entangled in a moving component Ideally electrical cables hoses pipes and fittings should be route...

Page 16: ...ner which complies with local and national regulations never dump fluids onto the ground Once the pump is free of all fluids it may be scrapped in accordance with local and national laws Cleaning Your...

Page 17: ...Undersize suction line or collapsed hose Suction line should be the same diameter as inlet port of Pump or larger Nozzle clogged Clear nozzle or replace Unloader or Relief Valve not functioning prope...

Page 18: ...p 5330C H Hollow Shaft with 5 8 I D 12E 1 5500 5315 Pump 5315C H Hollow Shaft with 5 8 I D 12F 1 5500 5320 Pump 5320C H Hollow Shaft with 5 8 I D 12G 1 5500 5325 Pump 5325C H Hollow Shaft with 5 8 I D...

Page 19: ...d 29 2 2008 0001 Main Bearing 30 2 1810 0013 Retaining Ring shaft 31 1 1820 0025 Retaining Ring housing 32 1 1510 0041 Mounting Base for Solid Shaft Models 33 1 3420 0030 Torque Arm Kit for Hollow Sha...

Page 20: ...Solid Shaft with 5 8 I D 22D 1 5500 5320 Hollow Shaft with 5 8 I D 24 2 2230 0017 Set Screws for Hollow Shaft 25 1 1610 0011 Spline Key for Hollow Shaft 28 1 2130 0007 Shield 29 2 2008 0001 Main Beari...

Page 21: ...0063 Cylinder Head Bolt 11A 4 2210 0064 Head Bolt 12 2 0201 5300CK Cylinder Head Cast Iron 13 2 1720 0038 O Ring 14 1 3430 0210 Ni Resist Cylinder Sleeve Assembly 14A 2 1830 0033 Retainer 14B 1 1720...

Page 22: ...Notes...

Page 23: ...able and must be addressed during installation by a third party Description PENTAIR Pump Type Roller Pumps Series Numbers 1502 1700 4001 4101 6500 7560 7700 Type Centrifugal Pumps Series Numbers 1442P...

Page 24: ...tagged before being shipped to Hypro for service or warranty consideration Hypro reserves the right to request a Material Safety Data Sheet from the returnee for any pump product it deems necessary Hy...

Reviews: