![Hypertherm XPR300 Instruction Manual Download Page 118](http://html1.mh-extra.com/html/hypertherm/xpr300/xpr300_instruction-manual_2193792118.webp)
Installation
3
118
809480
Instruction Manual
XPR300
How to install and connect the supply gases
WARNING
If you use oxygen as the plasma gas for cutting, it can cause a potential
fire hazard due to the oxygen-enriched atmosphere that collects.
Hypertherm recommends that you install an exhaust ventilation system
to remove the oxygen-enriched atmosphere that can collect when
oxygen is used as the plasma gas for cutting.
Flashback arrestors are
required
to stop the spread of fire to the supply
gases (unless a flashback arrestor is not available for a specific gas or
pressure).
You must supply the flashback arrestors for your cutting system. You
can get them from your cutting machine supplier.
Hydrogen is a flammable gas that presents an explosion hazard. Keep
flames away from cylinders and hoses that contain hydrogen. Keep
flames and sparks away from the torch when using hydrogen as a
plasma gas.
Consult your local safety, fire, and building code requirements for the
storage and use of hydrogen.
Hypertherm recommends that you install an exhaust ventilation system
to remove the hydrogen-enriched atmosphere that can collect when
hydrogen is used as the plasma gas for cutting.
Flashback arrestors are
required
to stop the spread of fire to the supply
gases (unless a flashback arrestor is not available for a specific gas or
pressure).
You must supply the flashback arrestors for your cutting system. You
can get them from your cutting machine supplier.
CAUTION
All hoses, hose connections, and hose fittings used for supply gas plumbing must be designed
for use with the appropriate gas and pressure rating.
NEVER connect a supply gas to a hose, connection, or fitting that is not designed for that gas
type or pressure.
If you replace any fittings on the consoles, or if you use the wrong fittings, it can cause the
internal valves to malfunction because contaminants can get into the valves.
Summary of Contents for XPR300
Page 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Page 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Page 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Page 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Page 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Page 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Page 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Page 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Page 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Page 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Page 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Page 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Page 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Page 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Page 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Page 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Page 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...