230V CE INSTALLATION
2-2
230V CE Installation Manual
WARNING
INSTALLATION MUST BE PERFORMED ONLY BY HYPERTHERM DISTRIBUTORS OR
QUALIFIED ELECTRONICS TECHNICIANS!!
SHOCK HAZARD: Always turn off power, unplug cord from wall and wait 5 minutes before
removing any cover of the power supply! If power unit is directly connected to a line
disconnect box, place line disconnect switch to OFF position. Lock out and tag out switch
before proceeding!
INSTALLATION
The installation of the 230V kit to the 400V CE Powermax900 involves 5 basic steps:
1.
Installation of wheels and casters to the transformer case.
2.
Attaching the power supply bracket to the Powermax900 chassis.
3.
Attaching the 230V case assembly to the Powermax900 bracket and chassis.
4.
Hooking up the three-phase transformer secondary power cord from the 230V
transformer case assembly to the Powermax900.
5.
Choosing the plug, power cord and line disconnect box fuse.