torch setup
powermax
45
Operator Manual
3-7
3. Disconnect the wires for the cap-sensor switch at the connector in the middle.
4. Use a #2 Phillips screwdriver and a 6 mm (1/4 inch) nut driver (or adjustable wrench) to remove the screw and nut
that secure the torch’s power cable to the plunger. (Turn the plunger if necessary to gain access to the screw.)
5. Use 6 mm (1/4 inch) and 10 mm (3/8 inch) or adjustable wrenches to loosen the nut that secures the gas supply
line to the torch lead. Set the torch body aside.
Note: Cover the end of the gas line on the torch lead with tape to keep dirt and other contaminants from getting
in the gas line when you route the lead through the track.
6. Route the torch lead through the cutting table’s track.
7. Reattach the torch’s power cable to the torch plunger using the screw and nut. Rotate the plunger so that the
screw does not interfere with the cap-sensor switch.
8. Reconnect the gas line to the torch lead.
9. Press the two halves of the cap-sensor switch’s wire connector together.
10. Slide the positioning sleeve over the torch body and check the alignment of the screw holes. Replace the three
screws at each end.
11. If you will be using the gear rack, re-attach it with the 2 black screws you removed earlier.
12. Attach the torch to the lifter per the manufacturer’s instructions.
Cap-sensor switch’s wire connector
Gas supply line connection
Screw to connect the power cable
to the plunger
Summary of Contents for POWERMAX 45
Page 1: ...45 Plasma arc cutting system Operator Manual 805780 Revision 2 ...
Page 6: ......
Page 10: ...Table of Contents iv powermax45 Operator Manual ...
Page 30: ...Power supply setup 2 8 powermax45 Operator Manual ...
Page 74: ...operation 4 16 powermax45 Operator Manual ...
Page 84: ...Maintenance and Repair 5 10 powermax45 Operator Manual ...