Disconnect P101/J101 at PCB14
( Fig. 4-3 [6] ). Measure voltage
between sockets 1 and 3 on
P101 for 11.5-12 VDC.
Disconnect P107/J107 at PCB13
( Fig. 4-6 [11] ). Measure voltage
between sockets 1 and 3 on J107
for 11.5-12 VDC.
Yes
No
No
Yes
Replace PCB14.
Replace voltage
regulator LM350
( Fig. 4-6 [9] ).
Replace voltage
regulator LM350
( Fig. 4-6 [9] or fan
M1 ( Fig. 4-7 [1] ).