OPeRATION
Duramax Retrofit Torch
Operator Manual
3-37
45 A Unshielded
Aluminum
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
best Quality Settings Production Settings
Cut
Speed
Voltage
Cut
Speed
Voltage
mm
mm
mm
%
seconds mm/min
Volts
mm/min
Volts
1
1.5
3.8
250
0.0
7400
126
11000
121
2
0.1
4400
127
9200
123
3
0.2
2800
129
6250
125
4
0.4
2100
132
4700
126
6
0.5
1050
135
2250
127
english
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
best Quality Settings Production Settings
Cut
Speed
Voltage
Cut
Speed
Voltage
in
in
in
%
seconds
ipm
Volts
ipm
Volts
1/32
0.06
0.15
250
0.0
325
126
450
121
1/16
0.1
200
126
400
122
3/32
0.2
150
127
328
124
1/8
0.4
100
130
224
125
1/4
0.5
36
136
72
127