OPeRATION
3-4
Duramax Retrofit Torch
Operator Manual
Process
Thickness (mm)
0.5
1
2
3
6
8
10
12
16
20
Mild Steel
100 A Shielded
2.0
2.1
2.2
2.2
2.3
2.7
85 A Shielded
1.7
1.8
1.9
2.0
2.2
2.4
2.6
80 A Shielded
1.7
1.7
1.8
1.8
1.8
2.0
2.3
65 A Shielded
1.6
1.6
1.8
1.9
2.0
2.2
2.3
60 A Shielded
1.4
1.4
1.6
1.6
1.7
1.8
1.9
45 A Shielded
1.1
1.1
1.4
1.5
1.7
FineCut
0.7
0.7
1.3
1.3
85 A Unshielded
1.7
1.8
1.9
2.0
2.1
2.1
2.3
65 A Unshielded
1.6
1.6
1.7
1.8
1.9
2.0
45 A Unshielded
0.5
0.9
1.3
1.3
Stainless Steel
100 A Shielded
1.9
1.9
2.0
2.1
2.2
2.3
85 A Shielded
1.6
1.8
1.9
2.1
2.3
2.4
2.5
80 A Shielded
1.7
1.7
1.8
1.8
1.9
2.1
2.2
65 A Shielded
1.4
1.5
1.8
1.9
2.0
2.2
2.4
60 A Shielded
1.5
1.5
1.6
1.7
1.8
1.8
2.0
45 A Shielded
0.9
1.1
1.5
1.6
1.8
FineCut
0.6
0.6
1.4
1.5
85 A Unshielded
1.7
1.7
1.8
1.9
2.1
2.2
2.4
65 A Unshielded
1.6
1.6
1.8
1.8
1.9
2.0
45 A Unshielded
0.5
1.0
1.3
1.5
1.5
Aluminum
100 A Shielded
2.1
2.1
2.1
2.1
2.1
2.3
85 A Shielded
2.0
1.9
2.0
2.1
2.2
2.4
2.6
80 A Shielded
1.7
1.7
1.7
1.8
1.8
1.8
65 A Shielded
1.9
1.9
1.9
2.0
2.1
2.3
2.5
60 A Shielded
1.5
1.5
1.5
1.5
1.6
1.6
1.6
45 A Shielded
1.5
1.5
1.6
1.5
85 A Unshielded
1.9
1.9
1.9
2.0
2.0
2.1
2.2
65 A Unshielded
1.8
1.8
1.8
1.8
1.9
2.0
45 A Unshielded
1.6
1.5
1.4
1.5
estimated kerf-width compensation – Metric (mm)
Summary of Contents for HRT
Page 1: ...Duramax Retrofit Torch HRT HRTs MRT Operator Manual 807190 Revision 1 ...
Page 2: ......
Page 10: ...WARRANTY 9 10 W 4 Compliance Information ...
Page 16: ...Specifications 1 4 Duramax Retrofit Torch Operator Manual ...
Page 34: ...Torch setup 2 18 Duramax Retrofit Torch Operator Manual ...
Page 88: ...OPERATION 3 54 Duramax Retrofit Torch Operator Manual ...