Field Service Bulletin 807570 Revision 0
5
Gas Console manifold Replacement
10. Remove the yellow hose loop from the old manifold and install it onto the new manifold. The old manifold can be
discarded.
Yellow hose
Install the new manifold
NOTES:
•
Always make sure the number on the valve matches the number on the connector
•
Refer to the pictures shown during the removal process when installing the new manifold
1.
Attach the connectors to valves SV1, SV5, and SV7 and tighten the phillips head screw to 0.7 Nm (6 in-lbs).
2.
Attach the connectors to valves SV2, SV3, SV4, SV6, SV8, SV9, SV10, SV11, and SV12.
3.
Attach the yellow hose and then the green hose to the front of the manifold.
4.
Slide the manifold back into place and secure it to the base of the enclosure with the phillips head screw that was
removed previously.
5.
Reconnect the communication cable and the valve power connector.
6.
Reconnect the hoses (red, green, black, and blue). Make sure the hoses are fully seated into the valve connection.
There is a mark on the hoses that indicates when the hose is fully inserted, but it may not still be visible in the field.
The tubing is fully seated when the mark is no longer visible.
7.
Reconnect the supply gas hoses and turn on the supply gases.
8.
Run the gas leak tests for the system. See your HPRXD instruction manual for details.