OPERATION
Duramax Retrofit Torch
Operator Manual
3-7
45A Shielded
Air flow rate - slpm/scfh
Aluminum
Hot
177 / 376
Cold
201 / 427
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
1
1.5
3.8
250
0.0
8250
136
11000
136
2
0.1
6600
136
9200
135
3
0.2
3100
139
6250
134
4
0.4
2200
141
4850
135
6
0.5
1500
142
2800
137
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
inches
inches
inches
%
seconds
ipm
Volts
ipm
Volts
1/32
0.06
0.15
250
0.0
325
136
450
136
1/16
0.1
325
136
400
136
3/32
0.2
200
136
328
134
1/8
0.4
100
140
224
134
1/4
0.5
54
142
96
137
220817
Shield
220854
Retaining cap
220941
Nozzle
220857
Swirl ring
220842
Electrode
45
A
220817
Shield
220941
Nozzle
220857
Swirl ring
220842
Electrode
220953
Ohmic-sensing
retaining cap
45
A