Hyperion IRT 1 PrepCure Assembly, Operation & Spares Manual Download Page 10

10

701011 rev 1

IRT 1 / IRT 2  PrepCure

Position

Qty

Art no

Description

1

1

714159  

Stand complete NA

2

1

713690

Base PrepCure red

3*

1

n/a

Upright 1400 mm

4

4

n/a

End cap 60 x 40 mm, 1-3

5*

1

n/a

End cap black 25 x 25 mm

6

1

420854

Cradle 

7

2

n/a

Washer SRKB M8 FZB 9XX28X2

8

1

n/a

Screw M8 x 45   8.8

9

2

n/a

Cap nut black M8

12

1

420856

Cable holder

13

1

n/a

Nut Nylock M8 FZB DIN 985

14

1

410009

Knob (wing) male M8

17

2

714158

Locking bracket cradle

18

4

n/a

Screw MRX M5X12 PH

19

4

n/a

Locking nut nylon M5 FZB

20

1

n/a

Screw M8x20 FZB

n/a  : not available as spare part

Stand for 

IRT 1 PrepCure
IRT 2 PrepCure

Spare parts

1

*) 3 + 5   

   

 421079           Upright with end cap

'UDZQE\

&HUWLILHGE\

Summary of Contents for IRT 1 PrepCure

Page 1: ...011 rev 1 IRT 1 IRT 2 PrepCure Hedson Technologies AB 2013 Assembly operation Spares manual Manuel d assemblage d utilisation et pi ces de rechange IRT 1 PrepCure IRT 2 PrepCure Superior Curing Techno...

Page 2: ...ctions to the owner 4 8 Maintenance 6 8 1 IR lamp replacement 6 9 Spare parts 8 10 Electric diagram 11 SOMMAIRE traduit d anglais 1 Instructions de montage 3 2 Domaine d utilisation 5 3 Caract ristiqu...

Page 3: ...IRT 2 PrepCure 2 3 9 8 7 12 13 1 Assembly Instructions Instructions de montage 7 Washer SRKB M8 FZB 8 Screw M8 x 45 8 8 9 Cap nut black M8 12 Cable holder 13 Nut Nylock M8 F2B DIN 985 150 7040 7 9 IRT...

Page 4: ...son an IR lamp should break the equipment must immediately be disconnected from the electrical outlet English 7 Instructions to the owner The owner of the infrared lamp is to draw up a list of instruc...

Page 5: ...recommand Sch ma lectrique voir page 11 4 Lieu d utilisation Si le s cheur manuel est utilis pour le s chage de la laque ou pour tout autre type de s chage comportant des solvants la ventilation du lo...

Page 6: ...cable is not damaged through improper use The cable should be checked for damage before each use Use a damp rag when cleaning the equipment Water can lead to risk for electrical flashover NOTE IRT 2...

Page 7: ...eflector Remove the protective paper from the lamp 8 Assemble the dryer in reverse order E F 6 Retirer la grille de protection E du r flecteur et desserrer un vis de la lampe F chaque extr mit de la l...

Page 8: ...2 410715 Side extrusion 7 2 420793 Gable 8 2 n a Nut M10 Black anodized 9 4 n a Washer 1 x 5 6 17 SWG 10 2 n a Screw M8x35 SKT A Head 11 1 74308 Plate heating shield 12 2 n a Screw MRX M5x12 FZ PH 13...

Page 9: ...2 713801 Protective mesh FF2 6 2 n a Washer star 6 4x11x2FZB DIN6798 7 2 102700 Lamp 1kW 230 V 8 1 714310 Sheet backside 9 2 421075 Endsheet 10 1 420745 Fan 230V 92x92 mm 11 2 n a Nut M10 12 1 714312...

Page 10: ...7 2 n a Washer SRKB M8 FZB 9XX28X2 8 1 n a Screw M8 x 45 8 8 9 2 n a Cap nut black M8 12 1 420856 Cable holder 13 1 n a Nut Nylock M8 FZB DIN 985 14 1 410009 Knob wing male M8 17 2 714158 Locking brac...

Page 11: ...11 701011 rev 1 IRT 1 IRT 2 PrepCure 11 Electrical diagram Elektrischer Schaltplan Sch ma lectrique Elschema Schema elettrico Diagrama el ctrico IRT 1 IRT 2 Z 3 1 3 4 Z 0 0 a 3 Z 4 1 3...

Page 12: ...re 57 7 14 13 HEDSON TECHNOLOGIES AB Box 1530 SE 462 28 V NERSBORG Sweden Tel 46 521 281000 Fax 46 521 66909 www hedson se HEDSON TECHNOLOGIES AB Hammarv gen 4 SE 232 37 ARL V Sweden Tel 46 40 53 42 0...

Reviews: