background image

Hyperion EOS0720iNET 3 Charger - 

User’s Manual 

Firmware version 3.1.  Visit http://media.hyperion.hk/dn/eos  for the newest manuals, firmware, and software

 

 

USB Cable also included but not pictured

 

Warnings: 

The EOS 0720iNET3 is a carefully-designed charger with many 
built-in safety features, such as reverse polarity protection, 
input voltage error warning, and cell-count mismatch 
warnings for lithium chemistry batteries.  HOWEVER, IT IS 
THE RESPONSIBILITY OF THE USER TO INSURE THAT THE 
CHARGER IS CONFIGURED AND USED IN A SAFE MANNER 
AND IN A PROPER ENVIRONMENT.  
 

 

Always be sure that the charger is properly 
configured for the correct battery type. 

 

Be sure that your lithium battery pack balance 
connector matches the multi-adapter type connected 
to the charger. 

 

Be sure that the batteries you charge are capable of 
charging at the rate you select. 

 

Never charge batteries unattended. 

 

Charge only in a fire-resistant environment, non-
flammable surfaces such as on concrete or brick. 

 

Do not charge near easily flammable materials. 

 

Do not charge batteries inside a model. 

 

Charging outdoors is recommended whenever 
practical. 

 

Use only high-quality gold 4mm bullet connectors for 
charge output cable connection to the charger.  See 
“setup”. 

 

Properly insulate and regularly inspect all connectors 
to eliminate the possibility of short circuit.  Damage 
caused by output short circuit is not covered by 
warranty. 

 

Never allow the charger case to contact an AC/DC 
power supply case while powered. 

 

Do not drop or cause other shock to the charger, nor 
subject it to moisture, condensation or liquids. 

 

Do not attempt to charge battery packs made from 
different types of cells, a mixture of old and new 
cells, or cells made with chemistry not supported by 
the EOS 0720i NET3. 

 

NEVER attempt to charge “non-rechargeable” cells 

 

Do not open the case of the charger under any 
circumstances.  Doing so will void the warranty. 

 

Keep the charger away from children and pets at all 
times.

 

 

 

 

HIGH RISK CHARGING ADVISORY

 

Avoid charging batteries indoors. If you must charge indoors – or any place 
injury to persons or damage to property could occur in the event of fire – 

then be sure to: 
* Keep battery well away from flammables (2 meters or more) 

* Contain battery in a heavy fireproof container (such as a brick box) 
* Always monitor the charge 
 

HYPERION ACCEPTS NO RESPONSIBILITY FOR DAMAGE 

OR INJURY DURING INDOOR, NON-MONITORED or other 

HIGH RISK CHARGE ACTIVITY

 

 

Specifications & Features:

  

 

12-bit Resolution

 for max accuracy 

 

250W max CHARGE Output 

 

0.1A to 

20.0A

 max Charge Current  in 0.1A steps 

(constrained by 250W max with 14.5V+ DC Input)

 

 

80W/10A max DISCHARGE limits 

 

STORE MODE allows fast and simple discharge to ~60% 
capacity for proper storage of Lithium Battery types = 
longer battery life. 

 

Charges/Discharges 1 to 7 cells Lithium Polymer Batteries

 

Per Port

 (3.7V/cell nominal types) 

 

 

Charges/Discharges 1 to 7 cells Lithium Ion Batteries Per 
Port 

(3.6V/cell nominal types)

 

 

Charges/Discharges 1 to 7 LiFePO4 (A123) cells 

(LiFePO4 3.3V/cell nominal, A123 3.3v support)

 

 

Charges/Discharges/Cycles 1-16 cell NiCd/Ni-MH in three 
modes: Normal, Linear, and Automatic  

 

Charges/Discharges 1~12 cell Lead Acid Batteries (Pb, 
2V/cell) 

 

Allows Lithium-Type batteries to 50,000mAh and PB 
(lead/acid) batteries to 100Ah capacity 

 

Built-in Hyperion LBA10 Balancer with 300mA max balance 
rate/cell and new 12-Bit measurement resolution 

 

TCS - Terminal Capacity Selection 

 

Rich Data Displays during and after charging and balancing 

 

USB

 PC Port for Data Logging, Firmware upgrades, and 

future Charger Control Software System 

(Nov1~Dec1 2009)

 

 

Temperature Sensor Ports & Temp Stop settings* 

 

Wide Voltage Input Range 11v~28v for higher efficiency 
when charging high-voltage packs, and compatibility with a 
wider selection of AC/DC power supplies 

 

Power Supply Amperage Control to allow reliable  charging 
with lower-output power supplies 

 

Power Supply Voltage Control (PS Load Control) works in 
concert with Amperage control to insure the charger does 
not overload your power supply 

 

Input Cable with 4mm Male Conn Clamps 

 

Output Cable Set Included, with 4mm Connectors 

 

Integral, Thermostat-Controlled Cooling Fans 

 

Rugged Aluminum Case with Insulating End Caps 

 

2-Line, 16-Character, Yellow Backlit LCD Data Display. 
Highly visible in all conditions 

 

20

 User-definable Memory Positions 

 

Firmware upgradable via Win PC**. USB Cable included. 

EOS0720iNET3 is designed to charge 

single

 Lithium-based 

packs up to 7S max. For flight packs larger than 7S, Network 
two NET3 in SYNC MODE to balance charge two separate packs, 
which after charge are series-wired to make the flight pack.  
(so 2x2S=4S up to 2x7S=14S series flight packs are possible) 

* Temp sensors available separate: #HP-EOSTMPSEN or EOS1210i-SEN 

** Firmware upgrades only available if/when improvements are identified in future. 

 

PUT SAFETY AHEAD OF ALL OTHER CONSIDERATIONS! 
SEEK MEDICAL ATTENTION IN EVENT OF ANY INJURY!

 

 

1

Summary of Contents for EOS0720iNET 3

Page 1: ... OR INJURY DURING INDOOR NON MONITORED or other HIGH RISK CHARGE ACTIVITY Specifications Features 12 bit Resolution for max accuracy 250W max CHARGE Output 0 1A to 20 0A max Charge Current in 0 1A steps constrained by 250W max with 14 5V DC Input 80W 10A max DISCHARGE limits STORE MODE allows fast and simple discharge to 60 capacity for proper storage of Lithium Battery types longer battery life C...

Page 2: ...VIEW And DATA QUICK VIEW screens UP DOWN Scroll through the settings within Menus Data Views and Selects values for Settings ENTER Selects any Setting to CHANGE short push and Charge START Charge STOP long push Attach the charger to an appropriate DC power supply Connect the Output Cable 4mm bullet connectors to the Red and Black output port on right side of the charger Connect your Battery Main C...

Page 3: ... screens you may be Additionally if balancer circuits are connected and you have two NET3 chargers networked by data cable SYNC MODE is available via ENTER short push and UP DOWN arrow keys With CHARGE START SOLO MODE selected hold down ENTER for 2 seconds Hold down ENTER again the charger will then read BATTERY CHECK and then ask you to confirm the number of cells in your battery pack Press ENTER...

Page 4: ...nd use UP or DOWN keys to select temperature display in degrees Fahrenheit or Celsius Press DOWN to scroll through the following screens and ENTER then UP or DOWN to change settings on each screen BUTTON SOUND screen ON or OFF FINISH SOUND TIME screen OFF ON continuous 1 Minute 15 Seconds 5 Seconds FINISH SOUND MELODY screen Choices 1 to 10 Will also play each Melody LIPO MAX C screen Choices of 1...

Page 5: ... is set to STOP the charger will stop charging at that TCS setting and if balancing is complete then give COMPLETE END Buzzer according to your buzzer settings or continue till balanced then give End buzzer There are three good reasons why you might want to charge a Lithium Battery to something less than full capacity The first is for long term storage Lithium batteries are best stored after charg...

Page 6: ...charged Wiggle the terminal clips into the battery posts to insure that you have a good connection Many charger problems are due to poor quality or inadequate switching AC DC power supplies so this test is necessary to eliminate those from the list of suspects 4 Try another battery for charging If the RC battery is in poor condition over discharged or in some other way defective the charger may co...