LiPo CHARGE
C=3000mAh 2S
LiPo CHARGE
C=3000mAh 3S
LiPo DISCHARGE
D=0.50 A 3S
Setting charge current
Adjust and find the desired charge current which ranges from 0.1A to 5.0A with INC & DEC
buttons. Press the ENTER button to confirm setting.
Setting discharge current
Adjust and find the desired discharge current, ranging from 0.1A to 1A, with INC & DEC buttons.
Press the ENTER button to confirm setting.
Setting discharge cutoff voltage
This is the voltage that the charger should stop discharging the battery.
Adjust and find total discharge cutoff voltages to be discharged from 0.1V to 16.8V with INC &
DEC buttons. Press the ENTER button to confirm setting.
Setting cycle
This is to set cycling with two options ( Charge to Discharge / Discharge to Charge). Set cycling
with INC & DEC buttons, and press the ENTER button to confirm setting.
LITHIUM POLYMER/ION MODE
(for 3.7V/cell types only!)
Setting LiPo battery capacity
Adjust and set the desired battery capacity from 100mAh to 5000mAh with INC & DEC buttons
(50mAh per step). Press the ENTER button to confirm setting. Charge rate is set on the basis of
selected capacity, at 1C rate. Example : Li-Po cell of 1500mAh capacity : 1C = 1500mAh ( = 1.5A ).
If your battery is larger than 5000mAh, you can charge it at the 5000mAh setting, but it will just
take longer to finish charging.
Setting battery voltages for LiPo battery packs
Select the total battery voltage to be charged with INC & DEC buttons: 1S=3.7V - single cell
2S = 7.4V - two-cell series pack
3S = 11.1V - three-cell series pack
4S = 14.8V - four-cell series pack
5S = 18.5V- five-cell series pack
NOTE: The EOS Series chargers have intelligent detection routines to help you avoid making
mistakes, and LOW or HIGH VOLTAGE errors are displayed if battery voltage does not match your
setting. HOWEVER, under some circumstances, especially with over-discharged or damaged
batteries, the safeguard could fail. Therefore, be absolutely sure that you have correctly set pack
voltage correctly before charging, every time!
Using LBA cell balancer with EOS Charger is
STRONGLY recommended, as it greatly increases safety.
Setting discharge parameters
Adjust to the desired discharge current from 0.10A to 1.00A (0.01A per step) with INC & DEC button.
Press the ENTER button to confirm setting. Set pack voltage, 1S~5S as in charging example above.
Autocut occurs automatically at 3.0V per cell.
LITHIUM POLY MODE IS ONLY FOR LITHIUM BATTERIES WITH 3.7V/cell RATING!
Some Li-Ion types are rated at 3.6V/cell, and CANNOT BE CHARGED with the EOS 5i!
LiPo CHARGE
C=3000mAh 3S
LiPo DISCHARGE
D=0.50 A 3S
LiPo CHARGE
C=3300mAh 3S
LiPo CHARGE
C=3000mAh 2S
BATTERY CHECK
WAIT PLEASE. . . .
CHG 0:00 00000
LP + 3.0 1.200
LiPo DISCHARGE
D=0.20A 3S
LiPo DISCHARGE
D=0.20A 4S
BATTERY CHECK
WAIT PLEASE. . . .
DCH 0:00 00000
LP + 3.0 1.200
START
NiCd CHARGE
C=3.0A
NiCd DISCHARGE
D=0.50A 4.8 V
NiCd DISCHARGE
D=0.50A 4.8 V
NiCd CYCLE C->D 5
C=3.0A D=0.50A
INC
INC
INC
INC
DEC
DEC
DEC
DEC
INC
DEC
BATT TYPE
START
ENTER
ENTER
ENTER
ENTER