background image

On Screen Help and Navigation 

Features are accessed by selection from a multi-level menu. Button numbers are shown in quotes for example 
‘A’, ‘B’, ‘C’ or ‘D’ and have an abbreviated description on the bottom row of the display. Button ‘A’ on the MAIN 

menu will display Tips on RDU and Emeter II firmware version upgrades. Navigation through the menus is 

achieved by pressing ‘D’ until the required menu item shows in larger characters. Once this occurs, 

 

press  ‘B’ to display screen help relating to the selected function or  

 

press ‘C’ to go to the selected function.  

There are two basic modes of operation – ‘Bench-Test’ mode in which the RDU and the Emeter II are connected 

for use together, and ‘In-Action’ mode where the RDU is used alone. In Bench-Test mode, RDU is cabled to the 
Emeter and data is recorded directly to the Emeter’s SD card, whereas In-Action mode stores the data in the 

remote RDU from which it is later copied to the Emeter II SD card.   After switching the Emeter II on, the 

function which was in use at the previous switch off time will re-appear. In most cases, ‘A’ will cause a return to 
the previous, higher menu item or screen. Certain actions may cause deletion of data which could be critical. 

You will be warned if this is the case and requested to confirm the action.

  

 

 

 

OPERATION NOTES 

EMETER BASIC SETUP 

 

Function Screen/Mode 

Cables/Wiring 

1.1 

Internal battery Charging 

 

12-15 volt supply with the supplied 4.5mm plug 

The Emeter II will automatically charge while connected to 12-15V PS whether the unit is in use, or switched off.  
The Emeter can be used while connected to 12-15V power source (i.e. during bench testing can be left connected) 
Charging will occur at 85 ma and take 9 - 12 hours at this rate from a fully discharged state. 
The battery will last between 18 and 50 hours, depending on use of screen backlight, connection to RDU and other factors. 
Main menu shows internal battery charge state indicator. Reconnect to 12-15V PS before this falls to 0%. The date and time 
will need to be reset if the internal battery is allowed to go flat. 

1.2 

Set Date/Time 

MAIN>EMETER SETUP 

 

Press ‘D’ (next) to move to date or time lines. 
Press ‘B’ or ‘C’ to decrease or increase the fields as required. Hold button down for accelerated change. 
These fields are used to add a timestamp to  log files or snapshots (see 4.1 – 4.3). 

Summary of Contents for Emeter II

Page 1: ...from some old toy router etc Please take time now to fit appropriate connectors to this cable and plug in your Emeter to a 12 15V power source for charging See details below for charge rate and time T...

Page 2: ...t cases A will cause a return to the previous higher menu item or screen Certain actions may cause deletion of data which could be critical You will be warned if this is the case and requested to conf...

Page 3: ...Set Gearbox ratio 1 for direct drive 2 3 Determine Motor Magnet Count READINGS TACHO push C CONFIG TACHO RDU RDU cable Phase Tach Run the motor at steady speed with Emeter II close to spinning prop V...

Page 4: ...Snapshots are retained when the Emeter II is turned off but for long term data retention see data logging facility 4 3 Snapshot Recall Clear READINGS SNAPSHOTS None Shows up to 8 snapshots taken from...

Page 5: ...DU optional RPM and temperature sensors NO RDU cable from RDU to Emeter II 3 wire cable from spare Rx channel to RDU Rx input for manual logging start Connect optional rpm sensor to RDU RPM port and a...

Page 6: ...her Emeter II functions such as Tacho or servo test without interrupting the countdown At the end of the specified time A 3 second long beep will sound even if the Emeter II is in use on a different s...

Page 7: ...le is to be executed Continuously or Once Only LOGGING Yes No Turns logging ON of OFF during the test run as desired THE FOLLOWING PARAMETERS WILL AUTO TERMINATE THE TEST according to your settings an...

Page 8: ...hing power to Emeter II SD card Firmware loader process checks for file EMFW bin on SD card and if found loads the new firmware version into the Emeter II 9 4 Upgrade RDU Firmware version MAIN RDU SET...

Page 9: ...f BEC ESC and a Brushless Motor 4 wire RDU to Emeter Data cable B C A Connect to Emeter Servo Driver Port To BEC ESC Also see http media hyperion hk dn em2 bottom of page for the Emeter II Suite PC So...

Reviews: