5. AFTER CONNECTING POWER SUPPLY
• After the connections have been secured, the floodlight front (Connection Box front) should be fastened to the
Connection Box using the 4 Connection Box Screws.
• Once screws are secure, the screw covers should be fitted [Fig.10]
• To secure the angle of light of the Mightylite Pro set the desired position, tighten the 2 Securing bolts then use the 2 x
Allen screws and washers to lock the position of the Mightylite Pro on the U bracket [Fig.11].
Fig. 10
Fig. 11
Ref:
Description:
Fascia:
Backplate:
Lens:
Wattage:
Lumens generated:
Voltage:
Power factor:
Efficiency:
Colour temperature:
Max. LED life
Operating temperature:
Fixed using mounting bracket:
Optional pipe bracket:
Dimensions (mm):
Weight (kg):
Warranty:
MLP240B
Mightylite PRO 240W Floodlight
Matt black polycarbonate
Matt black aluminium
Frosted
240W
26,000
80 -280V
>0.9
<75%
ANSI 5700K
50,000 hrs
-40°C to +60°C
Yes
Yes
220(H) x 325(W) x 125(D)
5.0
3 years
6. TECHNICAL SPECIFICATION
Fig. 9: Wiring for Four Lighting Levels (using 2 units)