©2020 Hylio Inc. All Rights Reserved

 

2

 

  

Contents

 

 

Daily Maintenance Checklist 

 

 

 

3

 

Maintenance Schedule 

 

 

 

 

Inspection Schedule 

 

 

 

 

Inspection Criteria 

 

 

 

 

Safety  

 

 

 

 

 

 

 

 

 

Safe Maintenance Guidelines 

 

 

 

 

Warning Signs    

 

 

 

 

 

Ground Testing  

 

 

 

 

 

 

 

When to Ground Test   

 

 

 

 

 

Ground Test Steps and Checks 

 

 

 

Flight Testing   

 

 

 

 

 

 

 

When to Flight Test 

 

 

 

 

 

 

Flight Test Steps and Checks 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for AgroDrone AG-110

Page 1: ...AgroDrone Spray System AG 110 Maintenance Manual V2 1...

Page 2: ...ntents Daily Maintenance Checklist 3 Maintenance Schedule 4 Inspection Schedule 4 Inspection Criteria 5 Safety Safe Maintenance Guidelines Warning Signs Ground Testing When to Ground Test Ground Test...

Page 3: ...TENANCE 4 Tighten screws on carbon fiber extension bar mounting plates 5 Inspect GPS bases Radar mounts motors drone base extension bar base and propellers for damage looseness or missing screws If yo...

Page 4: ...ll parts before resuming operation Part Flight Hours Propeller CCW CW 5 Rotor CCW CW 10 Ground Station Link Radio Antenna 5 Battery Connector as150u 10 GPS 5 GPS Mast 5 Obstacle Detection Radar 10 Alt...

Page 5: ...n GPS secured straight and tight to mast Double sided tape OK GPS housing and wire not damaged check closely at mount points and where wire enters frame Acceptable GPS accuracy performance GPS does no...

Page 6: ...Carbon Fiber Tubes Arms No visible cracks in carbon fiber tubes All screws tight and rust free Arm Elbow Joint No cracks can crack when CF mount screws overtightened No left right wobble tighten clasp...

Page 7: ...are indicators of a potential problem 1 Smell or appearance of electrical smoke from center frame or motors This occurs when there is an electrical short in the system 2 Visual wear on any wire housi...

Page 8: ...allon at 0 5 gallon per minute time how long it takes for tank to empty Should take 2 minutes If off by over 5 recalibrate flowmeter 6 While spraying check for any leaks in the spray system 7 Check ba...

Page 9: ...Check the motors are not making any unusual noises Check the drone appears to fly stable 7 As the drone descends to the mission area check that it yaws to face the mission line direction within accept...