Specifications
Before Starting Installation
Tools, Pipe, and Fittings, Other Materials
Pliers
Screwdriver
Teflon tape
Razor knife
Two adjustable wrenches
Additional tools may be required if modifi-
cation to home plumbing is required.
Plastic inlet and outlet fittings are included
with the softener. To maintain full valve
flow, 3/4” or 1” pipes to and from the sof-
tener fittings are recommended. You
should maintain the same, or larger, pipe
size as the water supply pipe, up to the
softener inlet and outlet.
Use copper, brass, or PEX pipe and fittings.
Some codes may also allow PVC plastic
pipe.
ALWAYS install the included bypass valve,
or 3 shut-off valves. Bypass valves let you
turn off water to the softener for repairs if
needed, but still have water in the house
pipes.
5/8” OD drain line is needed for the valve
drain. A 10’ length of hose is included.
with some models.
A length of 5/8” OD drain line tubing is
needed for the brine tank over flow fitting
(optional).
Nugget or pellet water softener salt is
needed to fill the cabinet or brine tank.
Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance.
The manufacturer reserves the right to make product improvements which may deviate from the specifications and
descriptions stated herein, without obligation to change previously manufactured products or to note the change.
Factory
Settings
‐
Iron
&
Manganese
Salt
Used
‐
Per
Regeneration
12.0
lbs
18.0
lbs
24.0
lbs
36.0
lbs
Water
Used
‐
Regeneration
52.2
gal
74.4
gal
101.4
gal
166
gal
Hardness
Removal
‐
Grains
30,000
45,000
60,000
90,000
Resin
Quantity
‐
Cubic
Feet
1.0
ft
3
1.5
ft
3
2.0
ft
3
3.0
ft
3
Tank
Size
9x48
10x54
12x52
14x65
Tank
Jacket
/
Media
Loaded
Yes
Yes
No
No
Brine
Tank
/
Cabinet
Size
(Inches)
18.1
x
34.5
20.3
x
37.4
20.3
x
37.4
23.0
x
40.5
Salt
Storage
Capacity
240
lbs
350
lbs
350
lbs
420
lbs
Flow
Rate
@
15
psi
Pressure
Drop
11.0
gpm
11.2
gpm
12.2
gpm
12.6
gpm
Flow
Rate
@
25
psi
Pressure
Drop
15.0
gpm
15.1
gpm
16.2
gpm
16.6
gpm
Back
Wash
Flow
Rate
2.1
gpm
2.4
gpm
3.5
gpm
5.0
gpm
Shipping
Weight
125
lbs
158
lbs
161
lbs
247
lbs
Regeneration
Type
Maximum
Hardness
Maximum
Iron
(Ferrous)
Maximum
Manganese
Plumbing
Connections
Resin
Type
Electrical
Requirements
Water
Temperature
Water
Pressure
Min.
20
‐
Max.
125
psi
Specifications
75
Grains
Per
Gallon
3/4"
(Optional
1")
Canature
High
Efficiency
Cation
Ion
Exchange
Resin
Input
120V
60
Hz
‐
Output
12V
650mA
Min
39
‐
Max.
100
degrees
Fahrenheit
10
ppm
5
ppm
Co
‐
Current
/
Down
Flow
585HIM
‐
100
585HIM
‐
150
585HIM
‐
200
585HIM
‐
300
785MBTO-100 785MBTO-150 785MBTO-200 785MBTO-300