background image

Warranty conditions

 

FW, TS and BT Series Interceptor units (and not complete systems) are covered by a 5-year Warranty. 
SR Series Interceptor units (and not complete systems) are covered by a 2-year Warranty. 
Recoil springs, electrical/electronic parts and devices come with a 2-year warranty. 
Anodes (consumables) are not included in the warranty (for BT, FW, TS Series). 
Hydrotab's warranty only covers the repair or replacement of spare parts. 

System selections 

It is the sole responsibility of the buyer to choose the correct system and even with Hydrotab’s suggestion for a system, the overall 
responsibility is with the buyer. 

Limited warranty

 

Provided that the system has being installed in accordance with the installation manual we provide, and no damage has been caused 
due to improper handling or practices, Hydrotab will replace any defective parts or parts that failed due to improper manufacturing 
withing the applicable warranty period. 
Hydrotab only covers the parts’ replacement. Fitting or shipping costs are not covered by warranty. 
Hydrotab will select if we will repair or replace any given part. 
Repaired or replaced products will assume the remainder of the warranty time and under no conditions will the full time of warranty be 
renewed. 

Limited warranty periods

 

Limited warranty period is two years (2 years) from the product shipment from our premises. 

Extended limited warranty period 

It is provided in case: 

a)

Hydrotab trim system is included as equipment of a newly purchased boat directly by from the boat-builder or his reseller.

b)

Hydrotab trim system has been purchased through a Hydrotab dealer.

The extended limited warranty period is valid for three (3) years from the shipping date, provided that the customer has downloaded, 
completed and submitted the online registration form within one month (30) days from the purchase in the following url. 

https://www.hydrotab.gr/product-registration 

In case the dealer sells separate units of Interceptors, Air Units and Controllers that constitute a full system that is not initially sold (as 
a complete system) by Hydrotab, the dealer has the responsibility to provide the separate Serial Numbers for the Interceptors, Air Units 
and Controllers and guide the end user for the proper registration of his serial numbers for the extended warranty to be valid. 

The authorized dealer is responsible for the product's service. 

For any services or spare parts requirements and replacements during warranty period, the original invoice is necessary to be 
presented. 
For the replacement of any part of the system (interceptors, Air Unit, any controller etc.) under warranty, the replaced parts must be 
returned to Hydrotab Marine Engineering for inspection, otherwise warranty is not valid. 
Cost of dismantling - assembly and spare parts transportation is borne by the user. 

The warranty does not foresee, under any circumstances, replacement of the whole Hydrotab system. 

What is not covered by the warranty: 

Damage caused by the lack or non-replacement of worn anodes (for BT, FW, TS Series). 
Damage caused by improper installation and use not consistent with the manual. 
Damage with external visible deformation of the product caused by misuse of the user or other external causes. 
Damage to any component caused during transportation, installation or repair from non-authorized personnel. 
Conversions or modifications made after the initial sale. 

N. Triantafyllis Ltd (Hydrotab Marine Engineering) is not liable for any incidental, indirect or consequential damages or losses, including,
without limitation: travel expenses, transport, lifting and hauling, costs, loss of income, loss of time, loss of property, loss of profits,
personal injury or damage of any products, different from those that the company distributes. Any further (except the above

m

entioned) commitment of the intermediate dealer regarding the sale terms or servicing of Hydrotab products does not create any

liability of our company.

Hydro

Tab

Marine Engineering

18

Summary of Contents for 300SR

Page 1: ...Hydro Tab Marine Engineering Hydrotab BT Series SR Series Rocker Switches Installation Operation Manual Hydro Tab Marine Engineering...

Page 2: ...gn patents pending Declaration of conformity This product conforms to the following Electromagnetic Compatibility EMC regulations and standards for use in marine environments CE EN 60945 Technical inf...

Page 3: ...7 Interceptor Installation Indirect Air Supply 9 Air Unit Installation 9 Installation Schematic overview One Set of Rocker Switches 11 Installation Schematic overview Two Sets of Rocker Switches 11 A...

Page 4: ...Interceptor mounting screws 6 3x32 Optional cables 20m 30m 40m 5 Connection cable 10m Lower edge of the trim unit Lower edge of the hull Use drill 5 5mm x 6holes 5 5mm x 6 SR300 Use drill 8 5mm 8 5mm...

Page 5: ...recautions WARNING 2 1 3 Right Wrong 1 For high speed boats overtrim may cause unexpectable turn Improper use of trim tabs may result to accident or injury 2 DO NOT PLACE YOUR FINGERS ON THE SIDES OF...

Page 6: ...ne correct the angle by using wedges or other means If the boat s transom has a significant curvature it is necessary to create a flat plane for the installation acceptable flatness tolerance 2mm Opti...

Page 7: ...n and drill according to the pattern indications 5 Tape Drill all the pattern holes with a 3mm bore without removing the pattern You will need No 3 7 Apply sealant Sikaflex 291 to the holes You will n...

Page 8: ...into the drilled hole 10 Apply Sikaflex to the interceptor You will need Sikaflex Gun M4 8x25 12 Mount the cap base to the transom Mount the interceptor to the transom 13 M6 3x32 5mm Allen Key No 5 M...

Page 9: ...9 Hydro Tab Marine Engineering Interceptor Installation indirect air supply In case of indirect air supply you can use the components included in the kit as shown in the image...

Page 10: ...g Connect the push in fitting After you install the hose through the transom mount the air fitting into the hose 5 Air Unit Installation 4 Pneumatic Connection Cut the 8mm pipe at the proper length an...

Page 11: ...cker Switches Panel Wiring Diagram 1 Fuse 10A Retract white wire Retract white wire Extend black white wire Extend black white wire Advice the fusing table and ensure that you apply the right fuse acc...

Page 12: ...Retract white wire Extend black and white wire Advice the fusing table and ensure that you apply the right fuse according to your boat s voltage Attention Made in Greece 12VDC FUSE 10A PORT STBD AIR...

Page 13: ...e Engineering Pneumatic Diagram Compressor PNE 01234 VALVE GROUP Exhaust Exhaust Compressor PNE 01234 C1 C2 SYMBOL PART No DESCRIPTION C1 PNE 01231C VALVE COIL C2 PNE 01231C VALVE COIL C1 C2 Port Valv...

Page 14: ...DY 1 2 GEN 00508 SR300 FRONT COVER 1 3 GEN 00507 SR300 BLADE 1 8 FAS 02549 SCREW 6 1x48 23 8 9 SPR 00037 SPRING 4 BOM ID PartNo Description QTY 12 GEN 00305 FITTING COVER 1 13 GEN 00306 FITTING COVER...

Page 15: ...DY 1 2 GEN 00522 SR450 FRONT COVER 1 3 GEN 00521 SR450 BLADE 1 8 FAS 02549 SCREW 6 1x48 23 10 9 SPR 00037 SPRING 6 BOM ID PartNo Description Qty 12 GEN 00305 FITTING COVER 1 13 GEN 00306 FITTING COVER...

Page 16: ...3 GEN 00157 BASE 1 4 LAS 01257 HOLDING FLANGE 1 5 PNE 00073 NIPPLE TAPER 1 8 M 1 8 M 2 6 PNE 00597 NON RETURN VALVE 1 8 F 1 8 F 2 7 PNE 00925 THREAD OPERATOR 2 2NC 2 8 PNE 01113 COIL NUT 2 9 PNE 01231...

Page 17: ...xtend Compressor operates NO YES NO Check Fuse Relay and Power Supply YES Solenoid Energized C3 C1 YES Valve outputs air Broken tubular or pipe NO Faulty Valve NO Burned coil or pilot Press RIGHT butt...

Page 18: ...tab gr product registration In case the dealer sells separate units of Interceptors Air Units and Controllers that constitute a full system that is not initially sold as a complete system by Hydrotab...

Page 19: ...19 Hydro Tab Marine Engineering Notes...

Page 20: ...20 Hydro Tab Marine Engineering 4 Papazoglou str GR 17778 Athens Greece email info hydrotab gr website www hydrotab gr REV B Hydro Tab Marine Engineering...