H16P USER MANUAL EDITION II 2017-05-18
4.3 setting crimping measurements
With the machine is a die set table packed that indicates the correct crimping measurement
interval for every die set. Crimping measurements that lie outside of the interval are not
recommended.
Turn the adjusting knob so that the zero (0) on the dial is lined-up with the zero (0) on the
scale. If zero (0) is set, the machine will crimp the smallest diameter provided in the
interval. Every revolution of the knob increases the value on the scale with one unit. One
turn clock-wise corresponds to 0.1 mm on the crimping measurement. The measurement
shall be added to the least-specified diameter in the interval.
Die set
Crimping area
16-10
16-12
16-14
16-16
16-19
16-23
16-27
16-31
Base Die
10-12 mm
12-14 mm
14-16 mm
16-19 mm
19-23 mm
23-27 mm
27-31 mm
31-36 mm
39-45 mm
H16 DIes
1
Die size marking
2.
Die set pin
2
1
For example: Crimping 16 mm hose requires die nr 16 with the adjusting knob set to zero (0)
and lined up with zero (0) in the window. Crimping 22,2 mm hose recommends die nr 19 with
the adjusting knob turned 3 (three) clock-wise rotations until 3 (three) on the scale and the
2 (two) on the dial is lined up with the zero (0) line on the scale.
The set crimping measurement values can differ slightly from the actual crimping
measurement because the machine’s die expansion and retraction. Compensate this by ad
-
justing the setting.
Adjusting knob dial
control Knob
Scale