A3: OFF
Panel Button Positions
Panel Button Assignments
A3:ON
1
1
2
3
4
2 3 4
1=Pump 2
2=Pump 1
3=Temp
4=Light
A1 Test Mode (normally OFF)
Control amp draw requirements (See Table 1)
A3 “ON” position: use Mini Panel
“OFF” position: use Digital Duplex or Light Duplex panel
A4 Aux Freeze (must be OFF)
A5+A9 Pump 1 speeds and Circ Modes:
A6 “ON” position: 50Hz operation
“OFF” position: 60Hz operation
A7 “ON” position: Standard mode only
“OFF” position: Std/Ecn/Sleep mode changes allowed
A8 “ON” position: temperature is displayed in degrees Celsius
“OFF” position: temperature is displayed in degrees Fahrenheit
Note: Panel layout is always Pump 2, Pump 1, Temp, Light
Table 1
# of
Pumps/Blower
Before Heat Disabled
A2
A10
OFF OFF
0
ON OFF
1
OFF ON
2
ON
ON
3
A1, Test Mode OFF
A7, Mode changes allowed
A2, See Table 1
A10, See Table 1
A9, Non-Circ Mode
A5, 2-speed P1
A 2+A10
Hi-Speed
Circuit Board Configurations
Dip Switch Chart for CS622*B
IMPORTANT:
Power off spa when making any dip switch changes.
Hot tubs equipped with pump 1 as a single speed pump must utilize a circulation pump as
the heater pump.
A5
A9
Circ Mode
Pump 1 Speed
OFF
OFF
Non-circ
2-speed
ON
OFF
1-speed
Thermostatically Controlled
OFF
ON
24 hours with 3°F shut-off
1-speed
ON
ON
24 hours with 3°F shut-off
2-speed
17
( * = 0,7,8,9 )