background image

20 

 

Low speed starts automatically for 1 minute every 30 min-
utes to detect the spa temperature (polling) and then to 
heat to the set temperature if needed. (in READY Mode 
only 

– see MODE

 

FUNCTION), 

or when a filter cycle is 

activated, or when a freeze condition is detected. 
 

PUMP AUTOMATIC TIME-OUT 
High speed – 

15 minutes 

Low speed – 

30 minutes 

 

FILTER CYCLES 

The system is factory programmed with one filter cycle 
that will run in the evening (assuming the time of day is 
properly set) when energy rates are lower. The filter time 
and duration are programmable. A second filter cycle can 
be enabled and programmed as needed. We recommend 
you start with as long a filter cycle as possible and over 
time, if you wish, you can reduce your filter cycles de-
pending on your usage, chemical program and overall 
water quality. 
 
At the start of each filter cycle Pump 2 (if there is one) will 
run briefly to purge its plumbing and maintain good water 
quality. The factory default is 4 hours per filter cycle. 

 
PROGRAMMING FILTER CYCLES 

To change the factory default filter cycle settings  

MODE FUNCTION (Ready and Rest) 

A combination of keypads is used to change hot tub op-
eration to either 

‘READY’ or ‘REST’ mode.

  

PUMP / JETS FUNCTION 

Press this pad to activate pump 1 and 
pump 2 (if equipped) 

1st press – 

turns on low speed (P1 only) 

2nd press – 

turns on high speed (1st press P2) 

3rd press – 

turns off pump (2nd press P2) 

When low speed is already operating, the 1st press 
of the pad puts the pump directly into high speed. 

At the main screen, begin by pressing TEMP

 

READY MODE 

READY mode will circulate the water every 30 minutes, 
using Pump1 Low, in order to maintain a constant water 
temperature, heat as needed, and refresh the tempera-
ture display. This is known as “polling”. 

 
REST MODE 

REST mode will only allow heating during programmed 
filter cycles. Since polling does not occur , the tempera-
ture display may  not show a current temperature until 
the heater pump has been running for a minute or two. 

PROGRAMMING MODE FUNCTION

 

 

Press LIGHT repeatedly until FLTR appears

 

Press TEMP to advance to the beginning of the 
time setting process for filtration. (F1 or F2)

 

TEMP advances to the first screen to change the 
time for F1 or F2. (BEGN will appear)

 

The hour will flash. Press TEMP to change the hour

 

Press LIGHT to advance to minutes

 

Press TEMP to change the minutes

 

Press LIGHT to set the Run Hours

 

Press TEMP to begin hour change for F1 or F2

 

Each TEMP press increments the hours

 

LIGHT press advances to minutes

 

Each TEMP press advances the time 15 minutes

 

Press LIGHT when finished

 

Press TEMP

 

Press LIGHT repeatedly until MODE appears

 

In MODE, TEMP button toggles between SET 
READY and SET REST

 

Choose SET READY or SET REST, then press  
LIGHT to set and exit.

 

SETTING THE CLOCK

 

At the main screen, begin by pressing TEMP

 

Press LIGHT repeatedly until TIME appears

 

Press TEMP at TIME (HRS begin to flash)

 

Press TEMP keys to change hours

 

Press LIGHT (minutes begin to flash)

 

Press TEMP keys to change minutes

 

Press LIGHT to exit

 

Summary of Contents for Serenity Hot Tubs

Page 1: ......

Page 2: ...Display Messages 22 23 Optional Variable Air Therapy System Control 23 Jet and Feature Operation 24 25 Jet Identification Chart 24 Jet Water Flow Adjustment 24 Jet Air Flow Adjustment 24 Interchanging...

Page 3: ...ns in this manual before electrically connecting your hot tub and adding water The following pages contain valuable information and pointers that will save you both time and money as well as help you...

Page 4: ...F THIS SPA OR HOT TUB 13 CHILDREN SHOULD NOT ENTER A HOT TUB WHERE THE WATER TEMPERATURE EXCEEDS BODY TEMPERATURE 37 C 98 6 F 14 DO NOT ALLOW CHILDREN TO SUBMERGE THEIR HEAD UNDER WATER 15 NEVER OPERA...

Page 5: ...PREVENT UNAUTHORIZED ACCESS BY CHILDREN TO AVOID ACCIDENTS ENSURE THAT CHILDREN CAN T USE THE SPA UNLESS THEY ARE SUPERVISED AT ALL TIMES 2 RISK OF INJURY THE SUCTION FITTINGS IN THIS SPA ARE SIZED TO...

Page 6: ...plashing water inside the home For those who choose an outdoor location hot tub operating temperatures can be adjusted to match the season In colder months many owners will operate their hot tub in th...

Page 7: ...cal plugs outlets and lights within 1 5m 5ft of the hot tub must be G F C I protected Con sult your electrician or local electrical au thority for further details Access to the hot tub must always be...

Page 8: ...r or not the tub is being installed in an area with freeze thaw conditions Hydro pool does not recommend back filling full in ground or partial in ground installations Non freezing climates it is suff...

Page 9: ...company for a tilt and load tow truck with a pulley winch system to pull the skid from the larger trailer to the lower profile tow truck flat bed The hot tub can be gently slid off the low profile tr...

Page 10: ...WG Canada Europe No 8 AWG USA 8 All field installed metal components such as rails ladders drains or other similar hardware within 3 m 10 ft of the hot tub shall be bonded to the equipment grounding b...

Page 11: ...ccordance with the National Electrical Code or the Canadian Electrical Code and all Federal State Provincial and local codes and regula tions in effect at the time of installation Hydropool highly rec...

Page 12: ...C D Circuit Breaker including ampere sizing and selection of conductor size and type must be performed by a qualified electrician in accordance with National Regional and Local Codes and Regulations i...

Page 13: ...ush the button to release the scent into the hot tub and repeat to add more liquid scent as desired please note by turning the button clockwise you can lock it so that any accidental pushing of the bu...

Page 14: ...OD touch or iPAD If your hot tub comes with this option installed you need to activate the App Store Icon from your IPOD menu Type in Balboa Water Group into the search field to find the application a...

Page 15: ...connections and plumbing for minor leaks In the event of a leak ensure all union con nections and pump plugs are tight and all o rings gaskets are in place STARTING Before applying voltage to power u...

Page 16: ...t do this more than 5 times Important Under NO circumstances should the pump s be allowed to operate without priming beyond 5 minutes as this may not only cause unwarrantable damage to the pump it may...

Page 17: ...Be sure that the pump is primed before exiting this mode TEMPERATURE CONTROL FUNCTIONALITY AND ADJUSTMENT SET TIME After the system exits PRIMING MODE it will ask you to SET TIME See the instructions...

Page 18: ...1 ILLUM KEY WHICH CONTROLS THE LIGHTING AND ACTIVATES THE LOW LEVEL PROGRAMMING TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROLLS THROUGH THE MENUS TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROL...

Page 19: ...WHICH CONTROLS THE LIGHTING AND ACTIVATES THE LOW LEVEL PROGRAMMING TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROLLS THROUGH THE MENUS TEMP KEY WHICH CONTROLS THE TEMPERATURE AND SCROLLS THROUGH TH...

Page 20: ...speed is already operating the 1st press of the pad puts the pump directly into high speed At the main screen begin by pressing TEMP READY MODE READY mode will circulate the water every 30 minutes usi...

Page 21: ...e pump or blower is turned off or times out The pump and ozone generator will run for 20 minutes or more depending on the system OPTIONAL OZONATOR The ozonator operates during FILTER CYCLES only when...

Page 22: ...ter temperature sensor is non functional SnA SENSOR A SERVICE RQD Spa has shut down sensor plugged into Sensor A port not working SnB SENSOR B SERVICE RQD Spa has shut down sensor plugged into Sensor...

Page 23: ...okay make sure that pumps are primed and all gate valves are fully opened Press any topside panel pad to reset RUN PMPS PURG AIR Priming mode occurs when spa is first powered up or when power has bee...

Page 24: ...ntrol is fully opened For maximum operating efficiency the air controls must remain closed when your hot tub is not in use INTERCHANGING JET INSERTS A great feature for custom tailoring the jets in yo...

Page 25: ...tub is equipped with a diverter valve It allows you to direct the flow of the water to different zones in your hot tub ALWAYS return the valve handle to the middle position be fore exiting the hot tub...

Page 26: ...ng upward on the handle 2 Remove the connector cover prior to plugging in your audio source Always keep the cover on when the docking station is not in use 3 Center the device over the Docking Station...

Page 27: ...micals with each other prior to adding to hot tub water Add only one chemical to the water at a time Always add chemicals to water and not vice versa Chemicals may be corrosive so handle with care and...

Page 28: ...e bicarbonate and hydroxide compounds present in the water that deter mines the ability or capacity of the water to resist change in pH Also known as the buffering capacity 11 ALKALINITY BOOSTER raise...

Page 29: ...s in the future Increase filter cycle time Laundry detergent residual in swimwear Prevent by running an extra rinse cycle on washing machine or re rinse well by hand Excess organic contaminants Some o...

Page 30: ...dge in a filter cartridge cleaning solu tion Rinse thoroughly and if possible allow to dry before re installing Hydropool recommends purchasing a second filter so that while the first is cleaning the...

Page 31: ...o remove remaining dirt particles Do not use a wire brush or other devise to clean cartridge element Do not put in dishwasher or washing ma chine RE INSTALLATION 11 Place the cartridge filter back int...

Page 32: ...polished using a soft cloth and acrylic cleaner available at your Hydropool Retailer Important Do not use detergents the re maining residues will adversely affect water chemistry making it difficult...

Page 33: ...a petroleum based lubricant as this will cause premature dete rioration of the lock seal PROTECTING YOUR CABINET WOOD FINISH Some HYDROPOOL hot tub cabinets are made from Western red cedar and are fac...

Page 34: ...ery important ALL water is re moved from the hot tub plumbing before adding Turn pump on for only a few seconds to circulate the anti freeze Unthread and disconnect all unions in the support equip men...

Page 35: ...partial messages try resetting the system by turn ing power to the hot tub off waiting a few minutes then turning power on again If this does not reset the system contact your local Hydropool retailer...

Reviews: