Hydro-Mix XT Skid Installation Guide HD0927 Rev: 1.0.0 21
Chapter 3
Troubleshooting
The following table list some common issues encountered with the Hydro-Skid. If you are unable to
diagnose the problem from the information, please contact your local distributor or the Hydronix
technical support team on: +44(0)1483 468900 or by e-mail:
Symptom
Possible cause
Action required
No change in
sensor reading
during operation.
Sensor not in contact with
the material.
Adjust the height of the
Hydro-Mix XT Skid.
Maintain minimum gap of
50mm from the conveyor
belt.
Sensor signal is
unstable
Sensor not fully in contact
with the material
Adjust the height of the
Hydro-Mix XT Skid.
Maintain minimum gap of
50mm from the conveyor
belt.
Material build-up
on the sensor
under the Hydro-
Mix XT Skid.
Sensor not installed flush
with the underside of the
Hydro-Mix XT Skid.
Adjust the position of the
sensor.
Material flows
over the top of the
Hydro-Mix XT
Skid covering the
sensor
Material level in front of
the Hydro-Mix XT Skid is
too high
Adjust the Hydro-Mix XT
Skid away from the
conveyor, ensuring the
sensor is in contact with the
material. Alternatively,
install levelling
plates/chains to reduce the
height
Sensor reading is
not close to zero
when the belt is
empty.
Hydro-Mix XT Skid is too
close to the belt.
Adjust the Height until the
reading is close to zero.
See section 3.3.
Summary of Contents for Hydro-MIX XT Skid
Page 4: ...4 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...
Page 6: ...6 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...
Page 8: ...8 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...
Page 10: ...10 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...
Page 12: ...Introduction Chapter 1 12 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...
Page 22: ...Troubleshooting Chapter 3 22 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...
Page 24: ...Document Cross Reference Appendix A 24 Hydro Mix XT Skid Installation Guide HD0927 Rev 1 0 0 ...