background image

Item # W-03-193  9/07

Part # 5625-193-1 

WARRAN

TY

Hydromatic

®

warrants to the original purchaser of each Hydromatic product(s) that any part

thereof that proves to be defective in material or workmanship within one year from date of installation or 
18 months from manufacture date, whichever comes first, will be replaced at no charge with a new or 
remanufactured part, F.O.B. factory. Purchaser shall assume all responsibility and expense from removal, 
reinstallation and freight. Any item(s) designated as manufactured by others shall be covered only by the 
express warranty of the manufacturer thereof. This warranty does not apply to damage resulting from
accident, alteration, design, misuse or abuse. The pump must be installed, operated and maintained in 
accordance with the published instructions of the appropriate Installation & Service Manual.

All dual seal non-clogs and 3–5 HP grinders must have seal failure and heat sensors attached and functional

for Warranty to be in effect. If a seal failure should occur, Hydromatic will cover only the lower seal and labor
thereof. Labor is based on Authorized Service Center contract allowance. If the heat sensor is not attached
and functional, Warranty is void. If the seal failure sensor is not attached and functional, Warranty is void.

If the material furnished to the Buyer shall fail to conform to this contract or to any of the terms of this 

written warranty, Hydromatic shall replace such nonconforming material at the original point
of delivery and shall furnish instruction for its disposition. Any transportation charges involved in such
disposition shall be for the Buyer’s account. The Buyer’s exclusive and sole remedy on account or in respect
of the furnishing of material that does not conform to this contract or to this written warranty, shall be to 
secure replacement thereof as aforesaid. Hydromatic shall not in any event be liable for the cost of any labor
expended on any such material or for any incidental or consequential damages to anyone by
reason of the fact that such material does not conform to this contract or to this written warranty.

ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY

AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED
TO THE SAME EXTENT AS THE EXPRESS WARRANTY CONTAINED HEREIN. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR 

CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED
WARRANTY ARISING IN CONNECTION WITH THIS PRODUCT, INCLUDING WITHOUT
LIMITATION, WHETHER IN TORT, NEGLIGENCE, STRICT LIABILITY CONTRACT OR 
OTHERWISE. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.

– Your Authorized Local Distributor –

USA

740 East 9th Street, Ashland, Ohio 44805

Tel: 419-289-3042  Fax: 419-281-4087

www.hydromatic.com

CANADA

269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5

Tel: 519-896-2163  Fax: 519-896-6337

© 2007 Hydromatic

®

Ashland, Ohio. All Rights Reserved.

Summary of Contents for SPD100H

Page 1: ...ffluent Pump SPD50H 100H NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Page 2: ... Pump Warning 7 For proper automatic operation make sure the pump power cord is plugged into the piggyback receptacle on the diaphragm switch cord 8 Connect to separate electrical circuit taken directly from main switch 9 Use steel or plastic pipe for all connecting lines between pump and sewer outlet Note Some city regulations do not allow installing a pump with plastic pipe Check local regulatio...

Page 3: ...n three phase pumps by reversing any two line leads No rotation check is necessary on single phase pumps 8 Closed discharge gate valve 9 Plugged impeller or pipeline 10 Discharge head may be too high Check elevation against design point of pump 11 Floats not hanging free in the sump 12 Malfunctioning floats Disconnect power supply Checking Power Cord To be sure wires are not burned off or broken i...

Page 4: ...4 SPD100H SPD50H ...

Page 5: ...er check any two leads Also check the third lead with either of the first two If a zero reading is indicated for any wire the wire is broken and a new power cord assembly must be ordered 11 If the winding is grounded remove the pipe plug in the top of the pump and drain the oil into a clear container A milky appearance to the oil will indicate that water has entered through worn or damaged seals o...

Page 6: ...e 7 and secure with four hex head screws 4 12 To replace the power cord 22 on single phase pumps as determined on page 5 first slip the stator lead wires through the holes in the wire seal assembly Coat the cord grip threads with pipe dope or apply Teflon tape and screw the new power cord assembly into the motor housing Referring to wiring diagrams in this manual secure wires together Do not tape ...

Page 7: ...ill seal chamber to 1 from top Replace plug 8 and stand pump up 14 Connect power cord wires to terminals in panel or connect power source and check pump running Motor should run smoothly and be free of vibration leaks fill the motor and seal housing with high grade transformer oil such as Sohio Factopure SE40 or equivalent to at least one inch below top of housing Do not fill the motor housing com...

Page 8: ...by plugging and unplugging cord Check vent hole in pump case for plugging 2 Pump head may be too high Pump cannot deliver water over SPD50H 50 or SPD100H 64 vertical Horizontal distance does not affect pumping except loss due to friction 3 Inlet in pump base may be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or partially plugged Remove pump and clean per...

Page 9: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 10: ... NPT 1 7 202 005 2 Volute Case 1 9 176 005 1 Screw Hex Hd 6 10 156 052 1 Washer 1 11 370 000 2 Impeller SPD100 1 11 8155 000 2 Impeller SPD50 1 12 404 002 2 Suction Bottom 1 13 Locktite Sealant 14 14525A010 Shaft Seal 1 15 6000 056 1 Wire Terminal Assembly 1 16 324 001 1 Gasket 1 17 19103A052 Screw Hex Hd 2 18 208 000 2 Discharge Flange 1 19 77 003 1 O Ring 2 20 12596 001 2 Housing Seal Bearing 1 ...

Page 11: ...4 001 1 Gasket 1 17 19103A052 19103A052 Screw Hex Hd 2 18 208 000 2 208 000 2 Discharge Flange 1 19 77 003 1 77 003 1 O Ring 2 20 12596 001 2 12596 000 2 Housing Seal Bearing 1 22 13216 000 5 n a Power Cord Assembly 10 w plug 115V 1 22 13216 001 5 n a Power Cord Assembly 20 w plug 115V 1 22 13216 002 5 13216 022 5 Power Cord Assembly 20 w plug 230V 1 22 11644 006 5 n a Power Cord Assembly 10 w S F...

Page 12: ...disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty shall be to secure replacement thereof as aforesaid Hydromatic shall not in any event be liable for the cost of any labor expended on any s...

Reviews: