Hydromatic SKV50 Installation And Service Manual Download Page 6

6

Pump
Troubleshooting

2. Impeller or volute openings

may be plugged or partially
plugged. Remove pump and
clean out.

3. Pump impeller may be partially

clogged causing motor to 
run slow, resulting in motor
overload. Clear impeller.

4. Fuse size or circuit breaker is

too small.

5. Defective motor stator: return

to authorized Hydromatic
service center for verification.

Motor runs for short time 
then stops. Then after short 
period starts again. Indicates
tripping overload caused by
symptom shown.

1. Inlet in pump base may be

clogged. Remove pump and
clean out openings.

2. Impeller or volute openings

may be plugged or partially
plugged. Remove pump and
clean out.

3. Pump impeller may be partially

clogged causing motor to 
run slow, resulting in motor
overload. Clear impeller.

4. Defective motor stator: return

to authorized Hydromatic
service center.

2. Switch contacts may be stuck;

replace switch.

Pump runs but delivers only
small amount of water.

1. Pump may be air locked. Start

and stop several times by
plugging and unplugging cord.
Check vent hole in pump case
for plugging.

2. Pump head may be too 

high. Pump cannot deliver
water over 24' vertical lift.
Horizontal distance does 
not affect pumping, except
loss due to friction through 
discharge pipe.

3. Inlet in pump base may be

clogged. Remove pump and
clean out openings.

4. Impeller or volute openings

may be plugged or partially
plugged. Remove pump and
clean out.

5. Pump impeller may be partially

clogged causing motor to 
run slow, resulting in motor
overload. Clear impeller.

Fuse blows or circuit breaker
trips when pump starts.

1. Inlet in pump base may be

clogged. Remove pump and
clean out openings.

Check vent hole in pump case
for plugging.

Hydromatic pumps have a
small air vent hole in the
impeller cavity to let out
trapped air.  If this hole
becomes plugged, pump may
air lock.  To break the air lock,
use a small screwdriver to
clear hole in the impeller
cavity.

As a secondary precaution in
installations of this type —
1/16" hole should be drilled in
the discharge pipe below the
check valve.  The check valve
should be 12 to 18 inches
above pump discharge. Do not
put check valve directly into
pump discharge opening.

NOTE: In sumps where the
pump is operating daily, air
locking rarely occurs.

4. Pump head may be too high.

Pump cannot deliver water
over 24' vertical lift.
Horizontal distance does not
affect pumping, except for
friction loss through the pipe.

5. Inlet in pump base may be

clogged.  Remove pump and
clean out openings.

6. Impeller or volute openings

may be plugged or partially
plugged.  Remove pump and
clean out.

Pump runs and pumps out
sump but does not stop.

1. Float is stuck in up position.

Be sure float is not hung up
and operates freely in basin.

Capacity-U.S. G.P.M.

Liters/Second

0

30

60

90

120

150

180

0

2

4

6

8

10

HEAD-FEET

HEAD-METERS

0

  10

40

30

20

0

  3

12

9

6

1/2 HP

SKV50 PERFORMANCE CURVE

Summary of Contents for SKV50

Page 1: ...ewage Ejector Pump SKV50 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Page 2: ... solid Raise the pump by placing bricks or concrete blocks underneath it 5 Use steel or plastic pipe for all connecting lines between pump and sewer outlet Note Some city regulations do not allow installing a pump with plastic pipe Check local regulations 6 In applications where the pump may sit idle for months at a time it is recommended that the pump s be cycled every month to ensure the pumping...

Page 3: ...olved the problem it may be in the electrical components of the pump Starting with the power cord inspect for cuts or nicks in the insulation If the cord is damaged replace it 5 Using the ohmmeter check the resistance of the motor windings by connecting one lead clip to each electrical flat prong on the power cord pump mud cement tar abrasives or chemicals If pump has been used for pumping of hot ...

Page 4: ...ft and rotor assembly If the bearing is rusted or feels rough when turned it should be replaced as in Step 13 12 Coat the replacement seal 6 with a thin oil dielectric same as in motor housing coating and use a plastic pusher to install the seal 6 into the seal plate 10 Do not use any sharp instruments that may damage the seal Do not chip scratch or mar the carbon face 13 If ball bearing replaceme...

Page 5: ...yback receptacle and plug the pump directly into the power source If the pump starts each time it is plugged directly into the receptacle and does not start each time when plugged into the piggyback switch with the float raised up to a start position replace the complete piggyback switch assembly and retest with new assembly 7 If all symptoms check OK motor winding may be open take to authorized s...

Page 6: ...r volute openings may be plugged or partially plugged Remove pump and clean out 5 Pump impeller may be partially clogged causing motor to run slow resulting in motor overload Clear impeller Fuse blows or circuit breaker trips when pump starts 1 Inlet in pump base may be clogged Remove pump and clean out openings Check vent hole in pump case for plugging Hydromatic pumps have a small air vent hole ...

Page 7: ...ll 230V Motor 1 14 14981 001 1 Pipe Plug 1 15 14623 010 1 Cord Assy 16 3 10 115V 1 15 14623 020 1 Cord Assy 16 3 20 115V 1 15 14623 210 1 Cord Assy 16 3 10 230V 1 15 14623 220 1 Cord Assy 16 3 20 230V 1 17 6000 053 1 Wire with Terminal 1 18 6000 061 1 Wire with Terminals 2 19 75 005 1 Cord Nut 1 20 139 014 1 Cord Grommet 1 21 13666 000 1 Ground Strap 1 FOR AUTOMATIC OPERATION Not 13967 011 5 Piggy...

Page 8: ... and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Se...

Reviews: