Hydromatic SHEF100 Installation And Service Manual Download Page 2

2

Thank you for purchasing your
Hydromatic

®

pump. To help

ensure years of trouble-free 
operation, please read the 
following manual carefully.

Before Operation: 

Read the following instructions
carefully. Reasonable care and
safe methods should be practiced.
Check local codes and 
requirements before installation.

Attention: 

This manual contains important
information for the safe use of
this product.  Read this manual
completely before using this
product and refer to it often for
continued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MANUAL.  Keep it
in a safe place so that you may
refer to it often.

WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use 
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.

To reduce risk of electrical shock:

1.

Risk of Electrical Shock:

This pump has not been

investigated for use in 
swimming pool areas.

2. 

Risk of Electrical Shock:

Connect only to a properly

grounded receptacle.

Septic tank is to be vented

in accordance with local
plumbing codes.

Do not smoke or use sparkable

electrical devices or flame in a
septic (gaseous) or possible
septic sump.

If a septic sump condition may

exist and if entry into sump is
necessary, then (1) provide
proper safety precautions per
OSHA requirements and (2)
do not enter sump until
these precautions are strictly
adhered to.

Do not install pump in location

classified as hazardous per
N.E.C., ANSI/NFPA 70 - 2001.

Failure to heed above  cautions

could result in injury or death.

General
Information

Pump
Warning

5. Do not remove ground pin

from electrical plug.

6. Do not use an extension cord.

7. For proper automatic 

operation, make sure the pump
power cord is plugged into 
the piggyback (1ø only) 
receptacle on the wide angle
switch cord. 3ø proper panel
connections required.

8. Connect to separate electrical

circuit taken directly from
main switch.

9. Use steel or plastic pipe for all

connecting lines between
pump and sewer outlet.

NOTE: Some city regulations
do not allow installing a pump 
with plastic pipe. Check local
code regulations.

10.In applications where the

pump may sit idle for months
at a time, it is recommended
that the pump(s) be cycled
every month to ensure the
pumping system is working
properly when needed.

11.Hydromatic check valve

should be installed in 
discharge pipe.

12.An audible alarm system such

as the Q Alert (indoor use
only) for high water conditions
should be installed in every
pump for greater protection.
Contact your Hydromatic 
distributor for additional 
panel applications.

Pump
Installation

These important instructions 
must be followed for satisfactory 
performance of your pump:

1. Provide proper sump 

(recommended minimum
sump diameter  is 24" for
SHEF50 & 30" for SHEF100).

2. Do not set pump directly on

the bottom of sump if it is not
solid. Raise the pump by using
bricks or concrete blocks 
underneath it or as your local
code requires.

3. Make sure sump is free of

string, cloth, nails, gravel, etc.
before installing pump.

4. Risk of electrical shock —

connect only to a properly
grounded receptacle.

Summary of Contents for SHEF100

Page 1: ...luent Pump SHEF50 SHEF100 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Pump Installation and Service Manual ...

Page 2: ...per N E C ANSI NFPA 70 2001 Failure to heed above cautions could result in injury or death General Information Pump Warning 5 Do not remove ground pin from electrical plug 6 Do not use an extension cord 7 For proper automatic operation make sure the pump power cord is plugged into the piggyback 1ø only receptacle on the wide angle switch cord 3ø proper panel connections required 8 Connect to separ...

Page 3: ...3 SHEF50 SHEF100 Typical Installation ...

Page 4: ...if water traps in the pump and it cannot get out thus preventing pump from operating Hydromatic pumps have a small air vent hole in the impeller cavity to let out trapped air If this hole becomes plugged pump may air lock To break the air lock use a small screwdriver to clear hole in the impeller cavity As a secondary precaution in installations of this type 1 16 hole should be drilled in the disc...

Page 5: ...motor assembly will have to be replaced Repeat for each leg or wire lead 8 Winding resistance test should be performed if the ground test is satisfactory Use ohmmeter with scale pointer set on R x 1 scale On this scale meter reads directly on ohms Always check the meter with leads together as described above under Ground Check test before making a reading of the winding Connect one meter lead to t...

Page 6: ...sibly burned or if the ground resistance test or the winding resistance test has failed Note that the replacement stator must be of the same manufacture as the existing rotor or vice versa Replace the stator bolts 7 Remove the old O ring 19 regardless of condition and replace Place the new O ring over the seal plate shoulder Do not roll it If twisted water may enter chamber and cause failure 8 Rea...

Page 7: ...ase for plugging 2 Pump head may be too high Pump cannot deliver water over SHEF50H 65 or SHEF100 90 vertical Horizontal distance does not affect pumping except loss due to friction 3 Inlet in pump base may be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or partially plugged Remove pump and clean per maintenance instructions 5 Pump impeller may be partial...

Page 8: ... 1 7 00202 004 2 Volute Case SHEF100 1 9 00176 003 1 Screw Hex Hd 1 4 20x 50 5 10 00517 010 1 Screw Hex 3 11 09640 001 1 Impeller SHEF50 1 11 09640 002 1 Impeller SHEF100 1 12 08521 004 1 Bottom Plate SHEF50 1 12 08521 005 1 Bottom Plate SHEF100 1 13 01754 000 1 Locktite Sealant 14 14525A010 Shaft Seal 1 15 13562 000 1 Gasket SHEF50 1 15 13562 001 1 Gasket SHEF100 1 16 12845 001 1 Machine Screw 8 ...

Page 9: ... Hd Cap 1 4 20x1 3 11 09640 001 1 Impeller SHEF50 1 11 09640 002 1 Impeller SHEF100 1 12 08521 004 1 Suction Bottom SHEF50 1 12 08521 005 1 Suction Bottom SHEF100 1 13 01754 000 1 Locktite Sealant 14 14525A010 Shaft Seal 1 16 13562 000 1 Gasket SHEF50 1 16 13562 001 1 Gasket SHEF100 1 19 00077 003 1 O Ring SHEF50 1 19 00077 003 1 O Ring SHEF100 2 20 12709 000 2 Adapter SHEF100 1 22 13216 001 5 Pow...

Page 10: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 11: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 12: ...disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty shall be to secure replacement thereof as aforesaid Hydromatic shall not in any event be liable for the cost of any labor expended on any s...

Reviews: